ArticleJournal of applied clinical medical physics2022

Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 1: Comparison of methods.

Michael Paul Barnes, Baozhou Sun, Brad Michael Oborn, Bishnu Lamichhane, Stuart Szwec, Matthew Schmidt, Bin Cai, Frederick Menk, Peter Greer

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Michael Paul BarnesDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.
Baozhou SunDepartment of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA.
Brad Michael ObornCentre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.
Bishnu LamichhaneSchool of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia.
Stuart SzwecSchool of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales, Australia.
Matthew SchmidtDepartment of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA.
Bin CaiDepartment of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA.
Frederick MenkSchool of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia.
Peter GreerDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCalibration of a radiotherapy electronic portal imaging device (EPID) using the pixel-sensitivity-map (PSM) in place of the flood field correction improves the utility of the EPID for quality assurance applications. Multiple methods are available for determining the PSM and this study provides an evaluation to inform on which is superior.

methodsThree different empirical methods ("Calvary Mater Newcastle" [CMN], "Varian," and "WashU") and a Monte Carlo-based method of PSM determination were investigated on a single Varian TrueBeam STx linear accelerator (linac) with an aS1200 EPID panel. PSM measurements were performed for each empirical method three successive times using the 6 MV beam. The resulting PSM from each method was compared to the Monte Carlo method as a reference using 2D percentage deviation maps and histograms plus crossplane profiles. The repeatability of generated PSMs was also assessed via 2D standard deviation (SD) maps and histograms. Additionally, the Beam-Response generated by removal of the PSM from a raw EPID image for each method was visually contrasted. Finally, the practicality of each method was assessed qualitatively and via the measured time required to acquire and export the required images.

resultsThe median pixel-by-pixel percentage deviation between each of the empirical PSM methods and the Monte Carlo PSM was -0.36%, 0.24%, and 0.74% for the CMN, Varian, and WashU methods, respectively. Ninety-five percent of pixels were found to be repeatable to within -0.21%, 0.08%, 0.19%, and 0.35% (1 SD) for the CMN, Monte Carlo, Varian, and WashU methods, respectively. The WashU method was found to be quickest for data acquisition and export and the CMN the slowest.

conclusionFor the first time four methods of generating the EPID PSM have been compared in detail and strengths and weaknesses of each method have been identified. All methods are considered likely to be clinically acceptable and with similar practical requirements.

Indexed as

Radiotherapy, Intensity-ModulatedCalibrationElectronicsHumansMonte Carlo MethodParticle AcceleratorsRadiometryRadiotherapy DosageEPID dosimetrypixel-sensitivity-map (PSM)quality assurance (QA)

Identifiers

PMID35429102
PMCPMC9195035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.