Evidence map›Paper›PMID 35428796›Full record

ArticleScientific reports2022

Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners.

Se Yeon Lee, Hoon Kim, Hyun-Joong Kim, Chooryung J Chung, Yoon Jeong Choi, Su-Jung Kim, Jung-Yul Cha

Registry-linked trialAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07273435 (Comparison of Predicted and Achieved Crown Movements in Adult Spacing Cases Treated With 3D Direct-printed Aligners), which is not on this map. Cited by 79 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
79citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07273435 narecruitingnot on this mapstarted 2025, after this paper: background citation

Comparison of Predicted and Achieved Crown Movements in Adult Spacing Cases Treated With 3D Direct-printed Aligners: A Prospective Clinical Trial

TypeinterventionalSponsorSuez Canal UniversityRan2025 to 2026Enrolled23ConditionsEffect of Direct Printed Aligners on Crown MovementArmsDirect printed aligners
3 · Its place in the literature

Who cites it

79 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Accuracy of three-dimensionally printed retainers and aligners : A systematic review.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2026
    Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Review

19 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Se Yeon Lee *Department of Orthodontics, College of Dentistry, Yonsei University, Seoul, Korea.
Hoon Kim *Research Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University, Seoul, Korea.
Hyun-Joong KimResearch Institute of Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University, Seoul, Korea.
Chooryung J ChungDepartment of Orthodontics, Gangnam Severance Hospital, Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, Seoul, Korea.
Yoon Jeong ChoiDepartment of Orthodontics, Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
Su-Jung KimDepartment of Orthodontics, Kyung Hee University School of Dentistry, Seoul, Korea.
Jung-Yul ChaDepartment of Orthodontics, Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea. jungcha@yuhs.ac.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To overcome the limitations of the conventional vacuum thermoforming manufacturing method, direct 3D printing of clear aligners has been developed. The present study investigated the thermo-mechanical and viscoelastic properties of a photocurable resin TC-85, which is a new material for the direct 3D printed clear aligners, comparing to a conventional thermoplastic material polyethylene terephthalate glycol. Dynamic mechanical analysis was performed to analyse the mechanical behaviours of the two materials at 37 °C and 80 °C, respectively. Furthermore, the shape memory property of the two materials was evaluated using a U-shape bending test, and the shape recovery ratio for 60 min at 37 °C was calculated. The results indicate that TC-85 can constantly apply a light force to the teeth when used for the 3D printed clear aligners, owing to its flexibility and viscoelastic properties. In addition, it is expected that the force decay induced by repeated insertion of the clear aligners will be reduced and a constant orthodontic force will be maintained. Furthermore, its geometric stability at high temperatures and the shape memory properties provide advantages for the clinical application.

Indexed as

Orthodontic Appliances, RemovableToothMechanical PhenomenaPrinting, Three-Dimensional

Identifiers

PMID35428796
PMCPMC9012852

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.