Evidence map›Paper›PMID 35426494›Full record

ArticleAnalytical and bioanalytical chemistry2022

Affimer sandwich probes for stable and robust lateral flow assaying.

Garima Goyal, Antareep Sharma, Alfred Iing Yoong Tok, Alagappan Palaniappan, Bo Liedberg

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Garima Goyal *Interdisciplinary Graduate School, Nanyang Technological University, Singapore, 639798, Singapore.
Antareep Sharma *Interdisciplinary Graduate School, Nanyang Technological University, Singapore, 639798, Singapore.
Alfred Iing Yoong TokSchool of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
Alagappan PalaniappanCenter for Biomimetic Sensor Science, Nanyang Technological University, Singapore, 637553, Singapore. alps@ntu.edu.sg.
Bo LiedbergInterdisciplinary Graduate School, Nanyang Technological University, Singapore, 639798, Singapore. bliedberg@ntu.edu.sg.
Nanyang Technological University · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Lateral flow assays (LFAs) widely deployed for on-site diagnosis have predominantly utilized antibodies as recognition molecules. Antibodies with limited thermal stability deteriorate the performance of the LFA over time. Herein, we demonstrate a stable and robust LFA by utilizing thermally stable peptide-based 12-14 kDa affimers as recognition molecules, in lieu of conventional protein-based antibodies to analyze complex samples with a significantly improved shelf life at room temperature. The model system studied here is that of interleukin-8 (IL8) biomarker for validating the efficacy of the proposed approach, using a pair of affimer probes that demonstrates dual functionality of capturing and reporting. Affimers immobilized on the test zone of LFA serve as capture probes for IL8-affimer-MB complexes. Whereas affimers conjugated with the MBs that enable extraction of IL8 from the sample matrix serve as reporters for visual detection. The MB complexes captured at the test zone resulted in brownish test bands that enable concentration-dependent detection of IL8. The assay yielded sensitive visual detection of IL8 at ng/mL levels (~ 0.1 ng/mL and 1 ng/mL in buffer and human plasma, respectively), within 20 min, using sample volumes of ~ 100 µL. Importantly, the stability of affimer-incorporated LFA improved significantly in contrast to antibody-incorporated LFA over time, even when stored at 4 °C. Therefore, the proposed affimer-based LFA in conjunction with MBs offer stable and reliable detection of biomarkers at clinically relevant concentration ranges in complicated matrices, even without requiring cold storage, hence, offering a promising avenue for on-site diagnosis in resource-limited settings.

Indexed as

Biological AssayInterleukin-8AntibodiesBiomarkersHumansImmunoassayPeptidesAntibodiesBiomarkersInterleukin-8PeptidesAffimerComplex matricesLateral flow assayMagnetic beadsPoint-of-careSample pre-treatment

Identifiers

PMID35426494
OpenAlexW4223957181

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.