Evidence map›Paper›PMID 35426473›Full record

ArticleMagnetic resonance in medicine2022

Optimization of through-time radial GRAPPA with coil compression and weight sharing.

James Ahad, Evan Cummings, Dominique Franson, Jesse Hamilton, Nicole Seiberlich

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

James AhadDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.ORCID 0000-0003-2415-2343
Evan CummingsDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Dominique FransonDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
Jesse HamiltonDepartment of Radiology, University of Michigan, Ann Arbor, Michigan, USA.ORCID 0000-0002-4463-481X
Nicole SeiberlichDepartment of Radiology, University of Michigan, Ann Arbor, Michigan, USA.

Funding

MEDICAL SCIENTIST TRAINING PROGRAMT32GM007250 · NIGMS · CASE WESTERN RESERVE UNIVERSITY · PI HUANG, ALEX YEE-CHEN · 1985 to 2023
$33.4M
Improved Cardiac and Vascular MRI Using Parallel Imaging and Compressed SensingR01HL094557 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI GRISWOLD, MARK, SEIBERLICH, NICOLE · 2010 to 2018
$4.5M
Real-Time MRI Guided Robotic Catheter System for Atrial Fibrillation AblationR01HL153034 · NHLBI · CASE WESTERN RESERVE UNIVERSITY · PI CAVUSOGLU, M. CENK, GRISWOLD, MARK · 2020 to 2023
$2.7M
Development of Real-time MR imaging and Visualization System to Improve MR-guided Prostate BiopsyF30CA239355 · NCI · CASE WESTERN RESERVE UNIVERSITY · PI AHAD, JAMES NOLAN · 2020 to 2022
$153k
NCI NIH HHS F30 CA239355NHLBI NIH HHS R01 HL094557NHLBI NIH HHS R01 HL153034NIGMS NIH HHS T32 GM007250
6 · The paper itself

Abstract

purposeThis work proposes principal component analysis (PCA) coil compression and weight sharing to reduce acquisition and reconstruction time of through-time radial GRAPPA.

methodsThrough-time radial GRAPPA enables ungated free-breathing motion-resolved cardiac imaging but requires a long calibration acquisition and GRAPPA weight calculation time. PCA coil compression reduces calibration data requirements and associated acquisition time, and weight sharing reduces the number of unique GRAPPA weight sets and associated weight computation time. In vivo cardiac data reconstructed with coil compression and weight sharing are compared to a gold standard to demonstrate improvement in calibration acquisition and reconstruction performance with minimal loss of image quality.

resultsCoil compression from 30 physical to 12 virtual coils (90% of signal variance) decreases requisite calibration data by 60%, reducing calibration acquisition time to 6.7 s/slice from 31.5 s/slice reported in original through-time radial GRAPPA work. Resulting images have small increase in RMS error (RMSE). Reconstruction with a weight sharing factor of 8 results in eight-fold reduction in GRAPPA weight calculation time with a comparable RMSE to reconstructions with no weight sharing. Optimized parameters for coil compression and weight sharing applied to reconstructions enables images to be collected with a temporal resolution of 66 ms/frame and spatial resolution of 2.34 × 2.34 mm while reducing calibration acquisition time from 34 to 6.7 s, weight calculation time from 200 to 3 s, and weight application time 18 to 5 s.

conclusionCoil compression and weight sharing applied to through-time radial GRAPPA enables fast free-breathing ungated cardiac cine without compromising image quality.

Indexed as

Data CompressionImage EnhancementAlgorithmsCalibrationCardiac Imaging TechniquesImage Processing, Computer-AssistedMagnetic Resonance Imagingcardiac imagingchannel compressionGRAPPAnon-Cartesianparallel imaging

Identifiers

PMID35426473
PMCPMC9246858

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.