Evidence map›Paper›PMID 35425874›Full record

ArticleResearch and practice in thrombosis and haemostasis2022

Analytical performance of the endogenous thrombin potential-based activated protein C resistance assay on the automated ST Genesia system.

Laure Morimont, Charline Leclercq, Marie Didembourg, Émilie De Gottal, Audrey Carlo, Ulysse Gaspard, Jean-Michel Dogné, Jonathan Douxfils

Open access · goldAbstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Chapter 3. Impact of estrogens on hemostasis.Frontiers in endocrinology · 2025
    Review
  3. Article
  4. Evaluation of Activated Protein C Resistance Using Thrombin Generation Test.Methods in molecular biology (Clifton, N.J.) · 2023
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Laure MorimontQualiblood sa Namur Belgium.ORCID https://orcid.org/0000-0001-9195-304X
Charline LeclercqDepartment of Gynecology Centre Hospitalier Régional de Huy Liège Belgium.
Marie DidembourgDepartment of Pharmacy Faculty of Medicine Namur Research Institute for Life Sciences (NARILIS) Namur Thrombosis and Hemostasis Center (NTHC) University of Namur Namur Belgium.
Émilie De GottalDepartment of Gynecology Centre Hospitalier Régional de Huy Liège Belgium.
Audrey CarloDiagnostica Stago Asnières-sur-Seine France.
Ulysse GaspardDepartment of Obstetrics and Gynecology University of Liège Liège Belgium.
Jean-Michel DognéDepartment of Pharmacy Faculty of Medicine Namur Research Institute for Life Sciences (NARILIS) Namur Thrombosis and Hemostasis Center (NTHC) University of Namur Namur Belgium.
Jonathan DouxfilsQualiblood sa Namur Belgium.ORCID https://orcid.org/0000-0002-7644-5298
University of Namur · BECentre Hospitalier Régional de Huy · BEStago (France) · FRUniversity of Liège · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The evaluation of activated protein C (APC) resistance based on the endogenous thrombin potential (ETP) is recommended during the development of steroid contraceptives in women. In 2019, this assay was validated on the calibrated automated thrombogram (CAT) device. However, in view of its screening potential, its automation is essential. Objectives: To transfer the ETP-based APC resistance assay on the ST Genesia system using reagent STG-ThromboScreen with exogenous APC added. Method: Dose-response curves were performed to define APC concentration leading to 90% ETP inhibition on healthy donors. Intra- and interrun reproducibility was assessed. The normal range was defined on the basis of 56 samples from healthy individuals. The sensitivity was assessed on 40 samples from women using combined oral contraceptives (COCs). A method comparison with the validated ETP-based APC resistance on the CAT system was performed. Results were expressed in normalized APC sensitivity ratio (nAPCsr). Results: The APC concentration leading to 90% ETP inhibition was 652 mU/mL. Intra- and interrun reproducibility showed standard deviation <4%. The nAPCsr normal range stood between 0.00 and 2.20. Analyses of 40 samples from women using COCs confirmed the good sensitivity of the assay. Compared to the CAT system, nAPCsr values were slightly higher on the automated system. Conclusion: This study is the first reporting the analytical performances of the ETP-based APC resistance assay on an automated platform. Results support the concept that this test, when incorporated into clinical routine, could become a promising regulatory and clinical tool to document on the thrombogenicity of female hormonal therapies.

Indexed as

activated protein C resistancecombined oral contraceptivesreproducibility of resultsthrombinvenous thromboembolism

Identifiers

PMID35425874
PMCPMC8988860
OpenAlexW4224012107

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked