Evidence map›Paper›PMID 35425765›Full record

ArticleFrontiers in bioengineering and biotechnology2022

Development of a Fluorescent Microfluidic Device Based on Antibody Microarray Read-Out for Therapeutic Drug Monitoring of Acenocoumarol.

J-Pablo Salvador, Thomas Brettschneider, Christian Dorrer, M-Pilar Marco

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 68% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

J-Pablo SalvadorCIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain.
Thomas BrettschneiderRobert Bosch GmbH, Applied Research 1-Microsystem Technologies, Microstructuring and Assembly (CR/ARY2), Stuttgart, Germany.
Christian DorrerRobert Bosch GmbH, Applied Research 1-Microsystem Technologies, Microstructuring and Assembly (CR/ARY2), Stuttgart, Germany.
M-Pilar MarcoNanobiotechnology for Diagnostics (Nb4D), Department of Surfactants and Nanobiotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Barcelona, Spain.
Robert Bosch (Germany) · DEBiomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine · ESInstitute of Advanced Chemistry of Catalonia · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The development of a proof-of-concept point-of-care (PoC) device for the determination of oral anticoagulants determination is presented. Acenocoumarol (ACL) is prescribed to prevent certain cardiovascular diseases related to the prevention of deep vein thrombosis, pulmonary embolism, myocardial infarction, and stroke. Oral anticoagualant treatment (OAT) represents a population of 2% under treatment which has expenditures about $ 144 million in 2011. The main drawback for OAT is the associated narrow therapeutic window and the unpredictable dose-response relationship, which is one of the main causes for visiting the emergency room at the hospitals. In a previous work, family antibodies were produced for the simultaneous detection of ACL and warfarin (W) depending on the area of application. It was developed in different formats, indirect and direct, either with similar detectabilities and both assays quantifying the oral anticoagulants with high accuracy and reproducibility. We present the implementation of the already developed immunochemical method to a point-of-care (PoC) device to assist on the patient compliance assessment programs. In order to achieve this goal, a first development was performed implementing ACL ELISA assay into a microarray format with fluorescent read-out. The assay was successfully implemented achieving a LOD of 1.23 nM of ACL directly measured in human plasma. Then, a fully integrated microfluidic system is developed which incorporates the specific immunoreagents for the detection of ACL. The immunoreagents were attached onto the glass slide in a microarray format. The system is automatic, rapid, sensitive, and disposable that could help clinicians monitor patients under OAT. According to the fluorescent label of the ACL binding, the chip can be easily read with a scanner. The microfluidic system performed good according to the robust and reproducible signals, and subsequently yielded an accurate result.

Indexed as

acenocoumarolantibodyfluorescencemicroarraymicrofluidic

Identifiers

PMID35425765
PMCPMC9002261
OpenAlexW4220918268

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.