Evidence map›Paper›PMID 35425275›Full record

ArticleRSC advances2022

Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors.

Ana Zubiarrain-Laserna, Shayan Angizi, Md Ali Akbar, Ranjith Divigalpitiya, Ponnambalam Ravi Selvaganapathy, Peter Kruse

Abstract read
In one paragraph

Article in RSC advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Long-term performance of low-cost free chlorine sensors to monitor on-site water reuse.Water science and technology : a journal of the International Association on Water Pollution Research · 2025
    Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ana Zubiarrain-LasernaDepartment of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada pkruse@mcmaster.ca.
Shayan AngiziDepartment of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada pkruse@mcmaster.ca.ORCID https://orcid.org/0000-0002-5345-4271
Md Ali AkbarDepartment of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada pkruse@mcmaster.ca.
Ranjith Divigalpitiya3M Canada Company 1840 Oxford Street London Ontario N5V 3R6 Canada.
Ponnambalam Ravi SelvaganapathyDepartment of Mechanical Engineering, McMaster University 1280 Main Street West Hamilton Ontario L8S 4L7 Canada.ORCID https://orcid.org/0000-0003-2041-7180
Peter KruseDepartment of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada pkruse@mcmaster.ca.ORCID https://orcid.org/0000-0003-4051-4375

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Free chlorine is the most commonly used water disinfectant. Measuring its concentration during and after water treatment is crucial to ensure its effectiveness. However, many of the existing methods do not allow for continuous on-line monitoring. Here we demonstrate a solid state chemiresistive sensor using graphene-like carbon (GLC) that overcomes that issue. GLC films that were either bare or non-covalently functionalized with the redox-active phenyl-capped aniline tetramer (PCAT) were successfully employed to quantify aqueous free chlorine, although functionalized devices showed better performance. The response of the sensors to increasing concentrations of free chlorine followed a Langmuir adsorption isotherm in the two tested ranges: 0.01-0.2 ppm and 0.2-1.4 ppm. The limit of detection was estimated to be 1 ppb, permitting the detection of breaches in chlorine filters. The devices respond to decreasing levels of free chlorine without the need for a reset, allowing for the continuous monitoring of fluctuations in the concentration. The maximum sensor response and saturation concentration were found to depend on the thickness of the GLC film. Hence, the sensitivity and dynamic range of the sensors can be tailored to different applications by adjusting the thickness of the films. Tap water samples from a residential area were tested using these sensors, which showed good agreement with standard colorimetric measurement methods. The devices did not suffer from interferences in the presence of ions commonly found in drinking water. Overall, these sensors are a cost-effective option for the continuous automated monitoring of free chlorine in drinking water.

Identifiers

PMID35425275
PMCPMC8979178

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.