Evidence map›Paper›PMID 35423544›Full record

ArticleRSC advances2021

Sulfur quantum dot-based "ON-OFF-ON" fluorescence platform for detection and bioimaging of Cr(vi) and ascorbic acid in complex environmental matrices and biological tissues.

Mengke Xia, He Mei, Qiuhui Qian, Randy A Dahlgren, Ming Gao, Xuedong Wang

Open access · goldAbstract read
In one paragraph

Article in RSC advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 28 citations in OpenAlex.

  1. Review
  2. Review
  3. Development of a Novel Sulfur Quantum Dots: Synthesis,Applied biochemistry and biotechnology · 2024
    Article
  4. Review
  5. Synthesis of Fluorescent Sulfur Quantum Dots for Bioimaging and Biosensing.Frontiers in bioengineering and biotechnology · 2022
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mengke XiaSchool of Environmental Science and Engineering, Suzhou University of Science and Technology Suzhou 215009 China zjuwxd@163.com gaoming@usts.edu.cn +86 512 6809 5950 +86 512 6809 5950.
He MeiCollege of Public Health and Management, Wenzhou Medical University Wenzhou 325035 China.
Qiuhui QianSchool of Environmental Science and Engineering, Suzhou University of Science and Technology Suzhou 215009 China zjuwxd@163.com gaoming@usts.edu.cn +86 512 6809 5950 +86 512 6809 5950.
Randy A DahlgrenCollege of Public Health and Management, Wenzhou Medical University Wenzhou 325035 China.
Ming GaoSchool of Environmental Science and Engineering, Suzhou University of Science and Technology Suzhou 215009 China zjuwxd@163.com gaoming@usts.edu.cn +86 512 6809 5950 +86 512 6809 5950.
Xuedong WangSchool of Environmental Science and Engineering, Suzhou University of Science and Technology Suzhou 215009 China zjuwxd@163.com gaoming@usts.edu.cn +86 512 6809 5950 +86 512 6809 5950.ORCID https://orcid.org/0000-0002-8343-0692
Suzhou University of Science and Technology · CNWenzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Based on an "assembling-fission" principle, stable sulfur quantum dots (SQDs) were synthesized using sublimed sulfur as a precursor and PEG-400 as a passivator. The fluorescence intensities (FIs) of SQDs were efficiently quenched by Cr(vi) due to formation of SQD/Cr(vi) complexes through the inner-filter effect. When ascorbic acid (AA) was introduced into the SQD/Cr(vi) system, SQD fluorescence was restored due to AA-induced reduction of Cr(vi) to Cr(iii). Consequently, a SQD-based "ON-OFF-ON" platform was constructed for sequential detection of Cr(vi) and AA. Under optimized conditions, the FIs of SQDs were linearly dependent on the concentrations of Cr(vi) and AA, yielding linear ranges of 0.005-1.5 and 0.01-5.5 mM with detection limits of 1.5 and 3 μM, respectively, in waters, serum and tablet samples. After a 24 h incubation, the SQDs displayed strong, quenched and recovered blue fluorescence, respectively, in the SQD, SQD/AAO/Cr(vi) and SQD/Cr(vi) systems in live HeLa cells and zebrafish embryos/larvae. A blue fluorescence was displayed in the yolk of zebrafish embryos, and yolk and head of larvae. This study demonstrates the efficacy of SQD systems for environmental and biological applications in complex matrices, and for direct observation of Cr bioaccumulation in organisms by bioimaging.

Identifiers

PMID35423544
PMCPMC8695692
OpenAlexW3137859080

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked