Evidence map›Paper›PMID 35420328›Full record

ArticleDie Anaesthesiologie2022

[Tracheal rupture following endotracheal intubation for an emergency cesarean].

S Kübler, N Kiefer, R Ciolka, R Rixecker, M Amarasekara, R K Ellerkmann

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Die Anaesthesiologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

S KüblerKlinik für Anästhesiologie, Operative Intensivmedizin, Schmerz- und Palliativmedizin, Klinikum Dortmund gGmbH, Beurhausstr. 40, 44137, Dortmund, Deutschland. Salwa.Kuebler@klinikumdo.de.
N KieferKlinik für Anästhesiologie und Operative Intensivmedizin, Marien Hospital Düsseldorf, Düsseldorf, Deutschland.
R CiolkaKlinik für Anästhesiologie, Operative Intensivmedizin, Schmerz- und Palliativmedizin, Klinikum Dortmund gGmbH, Beurhausstr. 40, 44137, Dortmund, Deutschland.
R RixeckerKlinik für Anästhesiologie, Operative Intensivmedizin, Schmerz- und Palliativmedizin, Klinikum Dortmund gGmbH, Beurhausstr. 40, 44137, Dortmund, Deutschland.
M AmarasekaraKlinik für Anästhesiologie, Operative Intensivmedizin, Schmerz- und Palliativmedizin, Klinikum Dortmund gGmbH, Beurhausstr. 40, 44137, Dortmund, Deutschland.
R K EllerkmannKlinik für Anästhesiologie, Operative Intensivmedizin, Schmerz- und Palliativmedizin, Klinikum Dortmund gGmbH, Beurhausstr. 40, 44137, Dortmund, Deutschland.
Klinikum Dortmund · DEMarien Hospital Düsseldorf · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This is a case report of a 45-year-old patient, 39 weeks of gestation, who was intubated via rapid sequence induction (RSI) for an emergency cesarean. The indication for emergency cesarean was a pathological cardiotocography during the ejection phase following labor induction.Despite the primary use of a video laryngoscope, there was difficulty aligning the laryngeal axis. Therefore, an internal stylet was used to heavily angulate the endotracheal tube (ETT) to a hockey stick shape to enter the larynx.Postoperative dyspnea and extensive facial swelling were initially diagnosed as an allergic reaction. Only 22 h later the diagnosis of tracheal rupture was confirmed following computer tomography.We hypothesized that the mechanism of injury was due to excessive pressure transmitted to the tip of the ETT. This probably occurred due to a leverage effect caused by the withdrawal of the heavily bent stylet from the ETT, forcing an intratracheal cranial movement of the ETT.By conducting an experiment on a pig's trachea, we were able to visualize this mechanism of injury. In addition, we were able to demonstrate that bending the stylet to a similar angle as the laryngoscope blade led to minimal movement of the tip of the ETT.Therefore, when using a stylet during intubation, we recommend bending the ETT and stylet to the shape of the used laryngoscope blade and retracting the stylet at a similar angle to avoid complications, such as tracheal rupture.

Indexed as

LaryngoscopesLarynxHumansIntubation, IntratrachealRuptureTracheaCesarean sectionComplicationEmergency intubationEmphysemaHockeystick

Identifiers

PMID35420328
OpenAlexW4223890772

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.