Evidence map›Paper›PMID 35419358›Full record

ArticleFrontiers in bioengineering and biotechnology2022

Design and Optimization of a New Anti-reflux Biliary Stent With Retractable Bionic Valve Based on Fluid-Structure Interaction Analysis.

Yushan Su, Zhongxia Xiang, Xiaofei Song, Shuxian Zheng, Xinsheng Xu

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Yushan SuKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, China.
Zhongxia XiangKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, China.
Xiaofei SongKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, China.
Shuxian ZhengKey Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, China.
Xinsheng XuNankai Hospital, Tianjin, China.
Tianjin University · CNTianjin Nankai Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Duodenal biliary reflux has been a challenging common problem which could cause dreadful complications after biliary stent implantation. A novel anti-reflux biliary stent with a retractable bionic valve was proposed according to the concertina motion characteristics of annelids. A 2D equivalent fluid-structure interaction (FSI) model based on the axial section was established to analyze and evaluate the mechanical performances of the anti-reflux biliary stent. Based on this model, four key parameters (initial shear modulus of material, thickness, pitch, and width) were selected to investigate the influence of design parameters on anti-reflux performance via an orthogonal design to optimize the stent. The results of FSI analysis showed that the retrograde closure ratio of the retractable valve primarily depended on initial shear modulus of material (

Indexed as

anti-refluxbiliary stentbionic valvefluid-structure interactionoptimization

Identifiers

PMID35419358
PMCPMC8995556
OpenAlexW4220963087

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.