Evidence map›Paper›PMID 35418587›Full record

ArticleScientific reports2022

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples.

Mikhail Lyubomirskiy, Felix Wittwer, Maik Kahnt, Frieder Koch, Adam Kubec, Ken Vidar Falch, Jan Garrevoet, Martin Seyrich, Christian David, Christian G Schroer

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
6.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 27 citations in OpenAlex.

  1. High-resolution ptychographic nanoimaging under high pressure with X-ray beam scanning.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  2. Article
  3. Article
  4. X-Ray Multibeam Ptychography at up to 20 keV: Nano-Lithography Enhances X-Ray Nano-Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  5. Dual-beam X-ray nano-holotomography.Journal of synchrotron radiation · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 4 countries.

Mikhail LyubomirskiyCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany. mikhail.lyubomirskiy@desy.de.
Felix WittwerCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Maik KahntMAX IV Laboratory, Lund University, Box 118, 221 00, Lund, Sweden.
Frieder Koch *Paul-Scherrer-Institut (PSI), Forschungsstr. 111, 5232, Villigen, Switzerland.
Adam Kubec *Paul-Scherrer-Institut (PSI), Forschungsstr. 111, 5232, Villigen, Switzerland.
Ken Vidar FalchCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Jan GarrevoetCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Martin SeyrichCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Christian DavidPaul-Scherrer-Institut (PSI), Forschungsstr. 111, 5232, Villigen, Switzerland.
Christian G SchroerCenter for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany.
Deutsches Elektronen-Synchrotron DESY · DEUniversität Hamburg · DEPaul Scherrer Institute · CHGSI Helmholtz Centre for Heavy Ion Research · DELund University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

Identifiers

PMID35418587
PMCPMC9008058
OpenAlexW4223939085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.