Evidence map›Paper›PMID 35416948›Full record

ArticleTranslational vision science & technology2022

Evaluation of the Blinq Vision Screener in the Detection of Amblyopia and Strabismus in Children.

Arnaud Devlieger, Abdelhakim Youssfi, Monique Cordonnier

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Arnaud DevliegerDepartment of Ophthalmology, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium.
Abdelhakim YoussfiDepartment of Ophthalmology, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium.
Monique CordonnierDepartment of Ophthalmology, Erasmus Hospital, Université Libre de Bruxelles, Brussels, Belgium.
Erasmus Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Amblyopia is a major health problem with an estimated 2% to 4% of the population affected. Screening combined with corrective measures, such as correction of refractive error and occlusion of the dominant eye, could reduce this prevalence. A new pediatric vision scanner, the blinq (Rebion, Boston, MA), studies the foveolar quality of fixation of each eye during binocular viewing. Based on the initial premise that poor quality foveolar or non-foveolar fixation is indicative of strabismus and, potentially of amblyopia, this study evaluates the effectiveness of the blinq screening device in detecting these two conditions compared to a standard ophthalmic examination (Gold Standard) based on the recommendations of the American Association for Pediatric Ophthalmology and Strabismus. Material and Methods: A prospective study was performed on a total of 101 children between 2 and 8 years of age. These children were offered a test by the blinq screening device before a standard ophthalmological examination in the ophthalmology department of the Erasmus Hospital in Brussels, Belgium. The two tests were then compared. Results: In a pediatric population heightened with amblyopia and strabismus (prevalence of 33.4%) and based on the Gold Standard Examination, the blinq device showed a specificity of 73.1% (95% confidence interval [CI] = 60.9%-83.2%) with a sensitivity of 91.2% (95% CI = 76.3%-98.1) to detect these conditions. The positive and negative predictive values were 63.3% (95% CI = 53.4%-72.2%) and 94.2% (95% CI = 84.6%-98%) respectively. The positive likelihood ratio (LR+) was 3.39 (95% CI = 2.26-5.11) for a negative likelihood ratio of 0.12 (95% CI = 0.04-0.36). Conclusions: The blinq device has good sensitivity, but insufficient specificity to be used alone in the first line of screening. Whereas other devices on the market detect risk factors that may lead to amblyopia, the blinq pediatric vision scanner detects poor foveolar fixation and strabismus, giving it a potential advantage in sensitivity to directly detect strabismus, including microstrabismus. The blinq does not detect refractive abnormalities, however, and will therefore need to be improved in the future to be used alone in pediatric vision screening. Translational Relevance: The blinq device detects visual axis alignment abnormalities with potential impact in the early detection of strabismus and subsequent associated amblyopia.

Indexed as

AmblyopiaStrabismusVision ScreeningChildHumansProspective StudiesSensitivity and Specificity

Identifiers

PMID35416948
PMCPMC9012885
OpenAlexW4223549482

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.