Evidence map›Paper›PMID 35415591›Full record

ArticleJournal of hand surgery global online2022

Intraoperative Fluoroscopy Versus Postoperative Radiographs in Assessing Distal Radius Volar Plate Position: Reliability of the Soong Classification.

Juston Fan, Ryne Jenkins, Roy J Caputo

Open access · goldAbstract read
In one paragraph

Article in Journal of hand surgery global online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Locking pegs versus locking screws in volar plating of distal radius fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Juston FanDepartment of Orthopaedic Surgery, Riverside University Health System Medical Center, Moreno Valley, CA.
Ryne JenkinsDepartment of Orthopaedic Surgery, Riverside University Health System Medical Center, Moreno Valley, CA.
Roy J CaputoDepartment of Orthopaedic Surgery, Riverside University Health System Medical Center, Moreno Valley, CA.
Riverside University Health System - Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Fluoroscopic imaging remains the standard intraoperative imaging modality for volar locking plate fixation of distal radius fractures, and correlation with postoperative radiographs remains unclear. The purpose of this study was to assess the reliability of the Soong classification system between intraoperative fluoroscopy and postoperative radiographs for distal radius volar plate position. Methods: Eleven hand surgery resident physicians (3 in postgraduate year 2, 2 in postgraduate year 3, 3 in postgraduate year 4, and 3 in postgraduate year 5) and 4 attending physicians classified images using the Soong classification system. Fluoroscopic and radiographic lateral images from 30 patients were randomized and deidentified. Thirty percent of the images were duplicated for intraobserver reliability. Seventy-eight images were randomized and presented to each observer in 1 consecutive session. Cohen kappa values were calculated for intraobserver reliability, and Fleiss kappa values were calculated for interobserver reliability. Results: Intraobserver reliability demonstrated moderate reliability overall. The intraobserver reliability was highest among postgraduate year 4 residents and attending physicians demonstrating substantial reliability. Lateral intraoperative fluoroscopic and postoperative radiographic imaging demonstrated no difference in intraobserver reliability overall. Interobserver reliability was highest among postgraduate year 5 residents demonstrating moderate reliability and attending physicians demonstrating substantial reliability. Conclusions: There was no difference in the intraobserver reliability of the Soong classification system between the lateral images of intraoperative fluoroscopy and postoperative radiographs. Fluoroscopic analysis using the Soong classification system is a reliable method to determine plate prominence and has demonstrated increasing reliability based on year of training. Fluoroscopic analysis using the Soong classification system and direct visualization during surgery for the assessment of plate prominence is recommended, with the understanding that higher Soong grades are associated with increased rates of complications. Type of study/level of evidence: Diagnostic III.

Indexed as

Distal radius fractureFluoroscopySoong classificationVolar plate position

Identifiers

PMID35415591
PMCPMC8991425
OpenAlexW3208460519

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.