Evidence map›Paper›PMID 35415519›Full record

ArticleJournal of hand surgery global online2020

Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic-Guided Navigation.

Akira Kawabata, Yusuke Sogabe, Yukiko Morimoto, Kiyohito Takamatsu

Open access · goldAbstract read
In one paragraph

Article in Journal of hand surgery global online, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Akira KawabataDepartment of Orthopaedic Surgery, Yodogawa Christian Hospital, Osaka, Japan.
Yusuke SogabeDepartment of Orthopaedic Surgery, Yodogawa Christian Hospital, Osaka, Japan.
Yukiko MorimotoDepartment of Orthopaedic Surgery, Yodogawa Christian Hospital, Osaka, Japan.
Kiyohito TakamatsuDepartment of Orthopaedic Surgery, Yodogawa Christian Hospital, Osaka, Japan.
Yodogawa Christian Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Unstable distal radius intra-articular fractures require restoration of alignment. Exact fixation of intra-articular fragments is ideal. Here, we employed intraoperative computed tomography (CT) navigation to insert screws accurately in the intra-articular dorsal fragments during treatment with a volar locking plate for distal radius intra-articular fractures. The main purposes of this study were to evaluate the accuracy of this procedure and the postoperative stability of the articular fragments through CT findings, as well as to assess clinical outcomes. Methods: This study included 26 patients with distal radius fractures, who were treated with a volar locking plate using intraoperative CT navigation with a minimum follow-up of 12 months. Mean patient age was 63 years and mean follow-up was 16 months. We examined the position of the inserted distal screws and articular displacement on preoperative, intraoperative, and post-bone union CT images. The 3 distal ulnar screw positions that influence the stability of the dorsoulnar articular fragment were evaluated. The Mayo wrist score and Disabilities of the Arm, Shoulder, and Hand score were also clinically evaluated. Results: Computed tomography evaluation revealed that the distal locking screws were appropriately inserted at the subchondral position, with sufficient length to stabilize the dorsal fragments, and reduction and stability of the articular fragment were acceptable. At the final follow-up, mean Mayo wrist score was 90.8 and mean Disabilities of the Arm, Shoulder, and Hand score was 9.6. Conclusions: Intraoperative CT navigation was successfully used for volar locking plate fixation of intra-articular distal radius fractures. Computed tomography evaluation revealed that the screws were precisely inserted for articular fragments and bone union was achieved, maintaining good intra-articular alignment. The findings demonstrate the accuracy of volar locking plate fixation assisted by intraoperative CT navigation and the good clinical outcomes of this procedure. Type of study/level of evidence: Therapeutic IV.

Indexed as

Computed tomographic navigationDistal radius fractureIntra-articular fractureIntraoperative computed tomographyVolar locking plate

Identifiers

PMID35415519
PMCPMC8991434
OpenAlexW3084427053

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.