Evidence map›Paper›PMID 35414978›Full record

ArticleBiomedical optics express2022

Spectroscopic thermo-elastic optical coherence tomography for tissue characterization.

Aaron Doug Deen, Heleen M M Van Beusekom, Tom Pfeiffer, Mathijs Stam, Dominique De Kleijn, Jolanda Wentzel, Robert Huber, Antonius F W Van Der Steen, Gijs Van Soest, Tianshi Wang

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 7 citations in OpenAlex.

  1. Closing the Loop: High-Precision 3D Photofabrication in Living Tissues.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Article
  3. Article
  4. Photoacoustic imaging plus X: a review.Journal of biomedical optics · 2024
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 3 countries.

Aaron Doug DeenDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.ORCID https://orcid.org/0000-0002-1318-2136
Heleen M M Van BeusekomDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Tom PfeifferInstitut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.
Mathijs StamDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Dominique De KleijnUniversity Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Jolanda WentzelDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Robert HuberInstitut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany.ORCID https://orcid.org/0000-0001-9785-6574
Antonius F W Van Der SteenDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Gijs Van SoestDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Tianshi WangDepartment of Cardiology, Erasmus University Medical Center, P.O. Box 2040, Rotterdam 3000 CA, The Netherlands.
Erasmus MC · NLUniversity of Lübeck · DEChinese Academy of Sciences · CNUniversity Medical Center Utrecht · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical imaging techniques that provide free space, label free imaging are powerful tools in obtaining structural and biochemical information in biological samples. To date, most of the optical imaging technologies create images with a specific contrast and require multimodality integration to add additional contrast. In this study, we demonstrate spectroscopic Thermo-elastic Optical Coherence Tomography (TE-OCT) as a potential tool in tissue identification. TE-OCT creates images based on two different forms of contrast: optical reflectance and thermo-elastic deformation. TE-OCT uses short laser pulses to induce thermo-elastic tissue deformation and measures the resulting surface displacement using phase-sensitive OCT. In this work we characterized the relation between thermo-elastic displacement and optical absorption, excitation, fluence and illumination area. The experimental results were validated with a 2-dimensional analytical model. Using spectroscopic TE-OCT, the thermo-elastic spectra of elastic phantoms and tissue components in coronary arteries were extracted. Specific tissue components, particularly lipid, an important biomarker for identifying atherosclerotic lesions, can be identified in the TE-OCT spectral response. As a label-free, free-space, dual-contrast, all-optical imaging technique, spectroscopic TE-OCT holds promise for biomedical research and clinical pathology diagnosis.

Identifiers

PMID35414978
PMCPMC8973171
OpenAlexW4205297648

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.