In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Multispectral label-freeJournal of biomedical optics · 2024
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Review
  13. Review
  14. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Janet A H TangThe Institute of Optics, University of Rochester, Rochester, NY 14627, USA.
Charles E GrangerThe Institute of Optics, University of Rochester, Rochester, NY 14627, USA.
Karteek KunalaCenter for Visual Science, University of Rochester, Rochester, NY 14627, USA.
Keith ParkinsCenter for Visual Science, University of Rochester, Rochester, NY 14627, USA.
Khang T HuynhCenter for Visual Science, University of Rochester, Rochester, NY 14627, USA.
Kristen Bowles-JohnsonCenter for Visual Science, University of Rochester, Rochester, NY 14627, USA.
Qiang YangCenter for Visual Science, University of Rochester, Rochester, NY 14627, USA.
Jennifer J HunterThe Institute of Optics, University of Rochester, Rochester, NY 14627, USA.
University of Rochester · US

Funding

VISUAL SCIENCE RESEARCH CTR SUPPORTP30EY001319 · NEI · UNIVERSITY OF ROCHESTER · PI Susana Marcos · 1985 to 2026
$17.5M
RETINAL MECHANISMS AND VISUAL RESOLUTIONR01EY004367 · NEI · UNIVERSITY OF ROCHESTER · PI HUNTER, JENNIFER J, WILLIAMS, DAVID R · 1986 to 2020
$7.3M
VISUAL SCIENCET32EY007125 · NEI · UNIVERSITY OF ROCHESTER · PI Krystel R Huxlin, Duje Tadin · 1990 to 2026
$7.1M
High-Resolution Functional Imaging of the RetinaR01EY022371 · NEI · UNIVERSITY OF WATERLOO · PI Jennifer J Hunter · 2012 to 2026
$4.1M
NEI NIH HHS P30 EY001319NEI NIH HHS R01 EY004367NEI NIH HHS R01 EY022371NEI NIH HHS T32 EY007125
6 · The paper itself

Abstract

The intrinsic fluorescence properties of lipofuscin - naturally occurring granules that accumulate in the retinal pigment epithelium - are a potential biomarker for the health of the eye. A new modality is described here which combines adaptive optics technology with fluorescence lifetime detection, allowing for the investigation of functional and compositional differences within the eye and between subjects. This new adaptive optics fluorescence lifetime imaging ophthalmoscope was demonstrated in 6 subjects. Repeated measurements between visits had a minimum intraclass correlation coefficient of 0.59 Although the light levels were well below maximum permissible exposures, the safety of the imaging paradigm was tested using clinical measures; no concerns were raised. This new technology allows for