ArticleBMC musculoskeletal disorders2022
A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Beyond linearity: a threshold effect links serum creatinine to SIRI in osteoporotic fractures.Frontiers in medicine · 2025Article
- Calcium phosphate cement promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes.BMC surgery · 2023Article
- A Novel Semi-Cannulated Screw Enhanced Bone Cement Augmentation and Pullout Strength in Posterior Cervical Lateral Mass Screw Fixations: An In Vitro Biomechanical and Morphological Study.Orthopaedic surgery · 2023Article
- Biomechanical Properties of Novel Lateral Hole Pedicle Screws and Solid Pedicle Screws: A Comparative Study in the Beagle Dogs.Orthopaedic surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe study aimed to (1) create a series of pedicle injectors with different number of holes on the sheath especially for the Chinese elderly patients and (2) further investigate the effects of the injectors on the augmentation of pedicle screw among osteoporotic lumbar pedicle channel.
methodsThis study used the biomechanical test module of polyurethane (Pacific Research Laboratory Corp, USA) to simulate the mechanical properties of human osteoporotic cancellous bone. The bone cement injectors were invented based on anatomical parameters of lumbar pedicle in Chinese elderly patients. Mechanical test experiments were performed on the bone cement injectors according to the three groups, namely, a local augmentation group, a full-length augmentation group, and a control group. The local augmentation group included three subgroups including 4-hole group, 6-hole group, and 8-hole group. All holes were laterally placed. The full-length augmentation group was a straight-hole injector. The control group was defined that pedicle screws were inserted without any cement augmentation. Six screws were inserted in each group and the maximum insertion torque was recorded. After 24 h of injecting acrylic bone cement, routine X-ray and CT examinations were performed to evaluate the distribution of bone cement. The axial pull-out force of screws was tested with the help of the material testing system 858 (MTS-858) mechanical tester.
resultsThe bone cement injectors were consisted of the sheaths and the steel rods and the sheaths had different number of lateral holes. The control group had the lowest maximum insertion torque as compared with the 4-hole, 6-hole, 8-hole, and straight pore groups (P < 0.01), but the differences between the 4-hole, 6-hole, 8-hole, and straight pore groups were no statistical significance. The control group had the lowest maximum axial pull-out force as compared with the other four groups (P < 0.01). Subgroup analysis showed the 8-hole group (161.35 ± 27.17 N) had the lower maximum axial pull-out force as compared with the 4-hole group (217.29 ± 49.68 N), 6-hole group (228.39 ± 57.83 N), and straight pore group (237.55 ± 35.96 N) (P < 0.01). Bone cement was mainly distributed in 1/3 of the distal end of the screw among the 4-hole group, in the middle 1/3 and distal end of the screw among the 6-hole group, in the proximal 1/3 of the screw among the 8-hole group, and along the long axis of the whole screw body in the straight pore group. It might indicate that the 8-hole and straight-hole groups were more vulnerable to spinal canal cement leakage. After pullout, bone cement was also closely connected with the screw without any looseness or fragmentation.
conclusionsThe bone cement injectors with different number of holes can be used to augment the pedicle screw channel. The pedicle screw augmented by the 4-hole or 6-hole sheath may have similar effects to the straight pore injector. However, the 8-hole injector may result in relatively lower pull-out strength and the straight pore injector has the risks of cement leakage as well as cement solidarization near the screw head.