ArticleJournal of digital imaging2022
Machine Learning-Aided Chronic Kidney Disease Diagnosis Based on Ultrasound Imaging Integrated with Computer-Extracted Measurable Features.
Article in Journal of digital imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.
- Applications of artificial intelligence in chronic kidney disease: a systematic review.Revista de saude publica · 2026Pooled it
- Diagnostic accuracy of AI-augmented renal ultrasound for degenerative kidney disorders: a systematic review and meta-analysis.Future science OA · 2026Review
- The diagnostic value of radiomics based on two-dimensional ultrasound in staging diabetic nephropathy.BMC medical imaging · 2026Article
- Mitochondrial dysfunction in Alzheimer's disease: connecting pathophysiology with neuroimaging.Frontiers in aging neuroscience · 2026Review
- Combined application of deep learning and conventional computer vision for kidney ultrasound image classification in chronic kidney disease: preliminary study.Ultrasonography (Seoul, Korea) · 2025Article
- A recursive embedding and clustering technique for unraveling asymptomatic kidney disease using laboratory data and machine learning.Scientific reports · 2025Article
- Deep learning in renal ultrasound: applications, challenges, and future outlook.Frontiers in oncology · 2025Review
- AI-based segmentation of renal enhanced CT images for quantitative evaluate of chronic kidney disease.Scientific reports · 2024Article
- Imaging-based deep learning in kidney diseases: recent progress and future prospects.Insights into imaging · 2024Review
- Value of radiomics-based two-dimensional ultrasound for diagnosing early diabetic nephropathy.Scientific reports · 2023Article
- Current progress in artificial intelligence-assisted medical image analysis for chronic kidney disease: A literature review.Computational and structural biotechnology journal · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although ultrasound plays an important role in the diagnosis of chronic kidney disease (CKD), image interpretation requires extensive training. High operator variability and limited image quality control of ultrasound images have made the application of computer-aided diagnosis (CAD) challenging. This study assessed the effect of integrating computer-extracted measurable features with the convolutional neural network (CNN) on the ultrasound image CAD accuracy of CKD. Ultrasound images from patients who visited Severance Hospital and Gangnam Severance Hospital in South Korea between 2011 and 2018 were used. A Mask regional CNN model was used for organ segmentation and measurable feature extraction. Data on kidney length and kidney-to-liver echogenicity ratio were extracted. The ResNet18 model classified kidney ultrasound images into CKD and non-CKD. Experiments were conducted with and without the input of the measurable feature data. The performance of each model was evaluated using the area under the receiver operating characteristic curve (AUROC). A total of 909 patients (mean age, 51.4 ± 19.3 years; 414 [49.5%] men and 495 [54.5%] women) were included in the study. The average AUROC from the model trained using ultrasound images achieved a level of 0.81. Image training with the integration of automatically extracted kidney length and echogenicity features revealed an improved average AUROC of 0.88. This value further increased to 0.91 when the clinical information of underlying diabetes was also included in the model trained with CNN and measurable features. The automated step-wise machine learning-aided model segmented, measured, and classified the kidney ultrasound images with high performance. The integration of computer-extracted measurable features into the machine learning model may improve CKD classification.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.