ArticleBioMed research international2022

The Impact of Location and Device Coupling on the Performance of the Osia System Actuator.

Guy Fierens, Charlotte Borgers, Tristan Putzeys, Joris Walraevens, Astrid Van Wieringen, Nicolas Verhaert

Abstract read
In one paragraph

Article in BioMed research international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. A Rare Case of Osia Extrusion. Our Management Proposal.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guy FierensKU Leuven-University of Leuven, Department of Neurosciences, Exporl, B-3000 Leuven, Belgium.ORCID https://orcid.org/0000-0003-0606-0103
Charlotte BorgersKU Leuven-University of Leuven, Department of Neurosciences, Exporl, B-3000 Leuven, Belgium.ORCID https://orcid.org/0000-0002-9319-1699
Tristan PutzeysKU Leuven-University of Leuven, Department of Neurosciences, Exporl, B-3000 Leuven, Belgium.ORCID https://orcid.org/0000-0002-0690-3636
Joris WalraevensCochlear Technology Centre, Mechelen, Belgium.
Astrid Van WieringenKU Leuven-University of Leuven, Department of Neurosciences, Exporl, B-3000 Leuven, Belgium.ORCID https://orcid.org/0000-0002-6320-7936
Nicolas VerhaertKU Leuven-University of Leuven, Department of Neurosciences, Exporl, B-3000 Leuven, Belgium.ORCID https://orcid.org/0000-0002-3512-1334

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant location, device coupling, and their influence on device performance. This study is aimed at quantifying the extent to which certain parameters affect device output when using the Osia® system actuator. Parameters under study are (1) implant location, (2) comparison with the actuator of a state-of-the-art BC device, (3) bone undergrowth simulation, and (4) skull fixation. Five human cadaveric heads were implanted with the actuator at three different implant locations: (1) recommended, (2) posterior Osia® positions, and (3) standard Baha® position. At each location, the cochlear promontory velocity and the intracochlear pressure difference were measured. A percutaneous bone conduction actuator was used as a reference for the obtained measurements. Stimulation levels corresponded to a hearing level of 60 dB HL for frequencies between 250 and 6000 Hz. In addition, bone cement was used as a simulation for reactive bone growth. Results obtained in four heads indicate an improved power transmission of the transcutaneous actuator when implanted at the recommended position compared to the actuator of the percutaneous device on its respective recommended location when stimulating at an identical force level. A correlation was found between the promontory vibration and the actuator position, indicating that the same level of stimulation leads to higher promontory vibrations when the device is implanted closer to the ear canal. This is mainly reflected at frequencies higher than 1 kHz, where an increase was observed in both measurement modalities. At lower frequencies (<1 kHz), the power transmission is less influenced by the implant position and differences between the acquired responses are limited. In addition, when no rigid coupling to the skull is provided, power transfer losses of up to 30 dB can be expected.

Indexed as

Bone ConductionHearing AidsCochleaHumansSkullVibration