ArticleSensors (Basel, Switzerland)2022
Dilute Polymerization of Aniline on PDMS Substrate via Surface Modification Using (3-Aminopropyl)Triethoxysilane for Stretchable Strain Sensor.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- The 0-3 Lead Zirconate-Titanate (PZT)/Polyvinyl-Butyral (PVB) Composite for Tactile Sensing.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
Stretchable strain sensors are capable of acquiring data when in contact with human skin or equipment and are widely used in wearable applications. Most strain sensors have tensile properties of less than 20% and have limitations regarding body motion linkage, complex sensor structure, and motion nonreliability. To address these problems, we developed a high tension and high sensitivity sensor with a gauge factor over 40 and tensile stress about 50%. Polydimethylsiloxane (PDMS) was selected as the flexible substrate to ensure tensile strength, and polyaniline (PANI) was used to measure the resistance changes in the sensor. In particular, problems regarding poor uniformity of PANI on PDMS were resolved by surface treatment of the PDMS, wherein PANI polymerization was performed sequentially after forming a self-assembled monolayer (SAM) on the PDMS substrate. O
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.