Evidence map›Paper›PMID 35408326›Full record

ArticleSensors (Basel, Switzerland)2022

Pose2Sim: An End-to-End Workflow for 3D Markerless Sports Kinematics-Part 2: Accuracy.

David Pagnon, Mathieu Domalain, Lionel Reveret

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Marker Data Enhancement for Markerless Motion Capture.IEEE transactions on bio-medical engineering · 2025
    Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Marker Data Enhancement For Markerless Motion Capture.bioRxiv : the preprint server for biology · 2024
    Article
  15. Article
  16. Review
  17. Effect of Foot Orthoses on Angular Velocity of Feet.Sensors (Basel, Switzerland) · 2023
    Article
  18. Article
  19. Towards Single Camera Human 3D-Kinematics.Sensors (Basel, Switzerland) · 2022
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

David PagnonLaboratoire Jean Kuntzmann, CNRS UMR 5224, Université Grenoble Alpes, 38400 Saint Martin d'Hères, France.ORCID 0000-0002-6891-8331
Mathieu DomalainInstitut Pprime, CNRS UPR 3346, Université de Poitiers, 86360 Chasseneuil-du-Poitou, France.ORCID 0000-0002-4518-8479
Lionel ReveretLaboratoire Jean Kuntzmann, CNRS UMR 5224, Université Grenoble Alpes, 38400 Saint Martin d'Hères, France.ORCID 0000-0002-0810-5187

Funding

ANR Equipex PIA 2011 (project Kinovis)ANR PPR STHP 2020 (project PerfAnalytics, ANR 20-STHP-0003)French National Centre for Scientific Research Doctoral Thesis 2019
6 · The paper itself

Abstract

Two-dimensional deep-learning pose estimation algorithms can suffer from biases in joint pose localizations, which are reflected in triangulated coordinates, and then in 3D joint angle estimation. Pose2Sim, our robust markerless kinematics workflow, comes with a physically consistent OpenSim skeletal model, meant to mitigate these errors. Its accuracy was concurrently validated against a reference marker-based method. Lower-limb joint angles were estimated over three tasks (walking, running, and cycling) performed multiple times by one participant. When averaged over all joint angles, the coefficient of multiple correlation (CMC) remained above 0.9 in the sagittal plane, except for the hip in running, which suffered from a systematic 15° offset (CMC = 0.65), and for the ankle in cycling, which was partially occluded (CMC = 0.75). When averaged over all joint angles and all degrees of freedom, mean errors were 3.0°, 4.1°, and 4.0°, in walking, running, and cycling, respectively; and range of motion errors were 2.7°, 2.3°, and 4.3°, respectively. Given the magnitude of error traditionally reported in joint angles computed from a marker-based optoelectronic system, Pose2Sim is deemed accurate enough for the analysis of lower-body kinematics in walking, cycling, and running.

Indexed as

RunningWalkingAnkle JointBiomechanical PhenomenaGaitHumansKnee JointMotionWorkflowaccuracycomputer visionconcurrent validitydeep learningkinematicsmarkerless motion captureOpenPoseOpenSimsports performance analysis

Identifiers

PMID35408326
PMCPMC9002957

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.