ArticleSensors (Basel, Switzerland)2022
Non-Invasive Muscular Atrophy Causes Evaluation for Limb Fracture Based on Flexible Surface Electromyography System.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Wearable Bioelectronics for Home-Based Monitoring and Treatment of Muscle Atrophy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
- Applications of flexible materials in health management assisted by machine learning.RSC advances · 2025Review
- Beyond Tissue replacement: The Emerging role of smart implants in healthcare.Materials today. Bio · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Muscular atrophy after limb fracture is a frequently occurring complication with multiple causes. Different treatments and targeted rehabilitation procedures should be carried out based on the causes. However, bedside evaluation methods are invasive in clinical practice nowadays, lacking reliable non-invasive methods. In this study, we propose a non-invasive flexible surface electromyography system with machine learning algorithms to distinguish nerve-injury and limb immobilization-related atrophy. First, a flexible surface electromyography sensor was designed and verified by in vitro tests for its robustness and flexibility. Then, in vivo tests on rats proved the reliability compared with the traditional invasive diagnosis method. Finally, this system was applied for the diagnosis of muscular atrophy in 10 patients. The flexible surface electromyography sensor can achieve a max strain of 12.0%, which ensures close contact with the skin. The in vivo tests on rats show great comparability with the traditional invasive diagnosis method. It can achieve a high specificity of 95.28% and sensitivity of 98.98%. Application on patients reaches a relatively high specificity of 89.44% and sensitivity of 91.94%. The proposed painless surface electromyography system can be an easy and accurate supplementary for bedside muscular atrophy causes evaluation, holding excellent contact with the body.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.