Evidence map›Paper›PMID 35408159›Full record

ArticleSensors (Basel, Switzerland)2022

Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking.

Timothy McGrath, Leia Stirling

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
18.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it, 43 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Timothy McGrathDepartment of Aeronautics and Astronautics, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA.ORCID 0000-0002-6582-0865
Leia StirlingIndustrial and Operations Engineering, University of Michigan, 1205 Beal Avenue, Ann Arbor, MI 48109, USA.ORCID 0000-0002-0119-1617
American Institute of Aeronautics and Astronautics · USUniversity of Michigan · US

Funding

National Science Foundation IIS-1453141
6 · The paper itself

Abstract

Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking).

Indexed as

Knee JointWalkingBiomechanical PhenomenaGaitHumansRange of Motion, ArticularbiomechanicsgaithiphumanIMUjoint anglekneeself-calibratingsoft tissue artifactstreadmillwalking

Identifiers

PMID35408159
PMCPMC9003309
OpenAlexW4220696593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.