Evidence map›Paper›PMID 35408102›Full record

ArticleSensors (Basel, Switzerland)2022

Tuning the Sensing Properties of N and S Co-Doped Carbon Dots for Colorimetric Detection of Copper and Cobalt in Water.

Ramanand Bisauriya, Simonetta Antonaroli, Matteo Ardini, Francesco Angelucci, Antonella Ricci, Roberto Pizzoferrato

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
  6. Optical Chemical Sensors: Design and Applications.Sensors (Basel, Switzerland) · 2023
    Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ramanand BisauriyaDepartment of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0001-8384-4724
Simonetta AntonaroliDepartment of Chemical Sciences and Technology, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0002-9053-0587
Matteo ArdiniDepartment of Life, Health and Environmental Sciences, University of L'Aquila, 67100 L'Aquila, Italy.ORCID 0000-0002-9044-3352
Francesco AngelucciDepartment of Life, Health and Environmental Sciences, University of L'Aquila, 67100 L'Aquila, Italy.
Antonella RicciFaculty of Bioscience and Technologies for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy.ORCID 0000-0002-7604-1584
Roberto PizzoferratoDepartment of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0002-6319-2519

Funding

Regione Lazio POR FESR LAZIO 2014 - 2020 Id: A0375-2020-36403
6 · The paper itself

Abstract

In this study, nitrogen and sulfur co-doped carbon dots (NS-CDs) were investigated for the detection of heavy metals in water through absorption-based colorimetric response. NS-CDs were synthesized by a simple one-pot hydrothermal method and characterized by TEM, STEM-coupled with energy dispersive X-ray analysis, NMR, and IR spectroscopy. Addition of Cu(II) ions to NS-CD aqueous solutions gave origin to a distinct absorption band at 660 nm which was attributed to the formation of cuprammonium complexes through coordination with amino functional groups of NS-CDs. Absorbance increased linearly with Cu(II) concentration in the range 1-100 µM and enabled a limit of detection of 200 nM. No response was observed with the other tested metals, including Fe(III) which, however, appreciably decreased sensitivity to copper. Increase of pH of the NS-CD solution up to 9.5 greatly reduced this interference effect and enhanced the response to Cu(II), thus confirming the different nature of the two interactions. In addition, a concurrent response to Co(II) appeared in a different spectral region, thus suggesting the possibility of dual-species multiple sensitivity. The present method neither requires any other reagents nor any previous assay treatment and thus can be a promising candidate for low-cost monitoring of copper onsite and by unskilled personnel.

Indexed as

CarbonQuantum DotsCobaltColorimetryCopperFerric CompoundsNitrogenSulfurWaterCarbonCobaltCopperFerric CompoundsNitrogenSulfurWatercolorimetrydivalent copperN and S co-doped carbon dotsoptical sensingwater quality

Identifiers

PMID35408102
PMCPMC9003535

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.