ArticleSensors (Basel, Switzerland)2022
The Conception of Test Fields for Fast Geometric Calibration of the FLIR VUE PRO Thermal Camera for Low-Cost UAV Applications.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Infrared Camera Geometric Calibration: A Review and a Precise Thermal Radiation Checkerboard Target.Sensors (Basel, Switzerland) · 2023Article
- Thermal Water Prospection with UAV, Low-Cost Sensors and GIS. Application to the Case of La Hermida.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The dynamic evolution of photogrammetry led to the development of numerous methods of geometric calibration of cameras, which are mostly based on building flat targets (fields) with features that can be distinguished in the images. Geometric calibration of thermal cameras for UAVs is an active research field that attracts numerous researchers. As a result of their low price and general availability, non-metric cameras are being increasingly used for measurement purposes. Apart from resolution, non-metric sensors do not have any other known parameters. The commonly applied process is self-calibration, which enables the determining of the approximate elements of the camera's interior orientation. The purpose of this work was to analyze the possibilities of geometric calibration of thermal UAV cameras using proposed test field patterns and materials. The experiment was conducted on a FLIR VUE PRO thermal camera dedicated to UAV platforms. The authors propose the selection of various image processing methods (histogram equalization, thresholding, brightness correction) in order to improve the quality of the thermograms. The consecutive processing methods resulted in over 80% effectiveness on average by 94%, 81%, and 80 %, respectively. This effectiveness, for no processing and processing with the use of the filtering method, was: 42% and 38%, respectively. Only high-pass filtering did not improve the obtained results. The final results of the proposed method and structure of test fields were verified on chosen geometric calibration algorithms. The results of fast and low-cost calibration are satisfactory, especially in terms of the automation of this process. For geometric correction, the standard deviations for the results of specific methods of thermogram sharpness enhancement are two to three times better than results without any correction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials