Evidence map›Paper›PMID 35407787›Full record

ArticleMaterials (Basel, Switzerland)2022

Mechanical Design Optimization of Prosthetic Hand's Fingers: Novel Solutions towards Weight Reduction.

Federica Buccino, Alessandro Bunt, Alex Lazell, Laura Maria Vergani

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Federica BuccinoDepartment of Mechanical Engineering (DMEC), Politecnico di Milano, Via La Masa 1, 20156 Milano, Italy.ORCID 0000-0002-2224-6322
Alessandro BuntDepartment of Mechanical Engineering (DMEC), Politecnico di Milano, Via La Masa 1, 20156 Milano, Italy.
Alex LazellHy5, Bygning 18 Raufoss Industripark, 2830 Raufoss, Norway.
Laura Maria VerganiDepartment of Mechanical Engineering (DMEC), Politecnico di Milano, Via La Masa 1, 20156 Milano, Italy.ORCID 0000-0003-2353-7751
Politecnico di Milano · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

From the mechanical function of grabbing objects to the emotional aspect of gesturing, the functionality of human hands is fundamental for both physical and social survival. Therefore, the loss of one or both hands represents a devastating issue, exacerbated by long rehabilitation times and psychological treatments. Prosthetic arms represent an effective solution to provide concrete functional and esthetical support. However, commercial hand prostheses still lack an optimal combination of light weight, durability, adequate cosmetic appearance, and affordability. Among these aspects, the priority for upper-limb prosthesis users is weight, a key parameter that influences both the portability and the functionality of the system. The purpose of this work is to optimize the design of the MyHand prosthesis, by redesigning both the proximal and distal finger and thumb in light of finding an optimal balance between weight reduction and adequate stiffness. Starting from elastic-plastic numerical models and experimental tests on obsolete components, analyzed under the worst loading condition, five different design solutions are suggested. An iterative topology optimization process locates the regions where material removal is permitted. From these results, 2 mm geometrical patterns on the top surface of the hand prosthesis appear as the most prominent, preventing object intrusion.

Indexed as

finite element modelshand prostheseslightweight designselective laser meltingtopology optimization

Identifiers

PMID35407787
PMCPMC8999927
OpenAlexW4220890013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.