ArticleJournal of clinical medicine2022
Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects-A Retrospective Study.
Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Comparative Safety and Efficacy of Patient-Specific Versus Hand-Molded Implants in Cranioplasty: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2025Review
- Review
- Neuroplastic Surgery Principles of Computerized Surgical Planning in Complex Cranioplasty Reconstruction.Seminars in plastic surgery · 2024Review
- Cranial Repair in Children: Techniques, Materials, and Peculiar Issues.Advances and technical standards in neurosurgery · 2024Review
- Development of 3D printed patient-specific skull implants based on 3d surface scans.3D printing in medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cranioplasties show overall high complication rates of up to 45.3%. Risk factors potentially associated with the occurrence of postoperative complications are frequently discussed in existing research. The present study examines the positioning of 39 patient-specific implants (PSI) made from polyetheretherketone (PEEK) and retrospectively investigates the relationship between the fitting accuracy and incidence of postoperative complications. To analyze the fitting accuracy of the implants pre- and post-operatively, STL files were created and superimposed in a 3D coordinate system, and the deviations were graphically displayed and evaluated along with the postoperative complications. On average, 95.17% (SD = 9.42) of the measurements between planned and surgically achieved implant position were within the defined tolerance range. In cases with lower accordance, an increased occurrence of complications could not be demonstrated. The overall postoperative complication rate was 64.1%. The fitting of the PEEK-PSI was highly satisfactory. There were predominantly minor deviations of the achieved compared to the planned implant positions; however, estimations were within the defined tolerance range. Despite the overall high accuracy of fitting, a considerable complication rate was found. To optimize the surgical outcome, the focus should instead be directed towards the investigation of other risk factors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.