Novel Mode of Near-Infrared Spectroscopy as a Continuous Cerebral Physiological Monitoring Device during Cardiopulmonary Resuscitation: Four Case Reports.

Tasuku Matsuyama, Yuki Yasutake, Daichi Inaba, Hideaki Yoshihara, Keisuke Bando, Toshihisa Matsui, Masaki Nagama, Hitoshi Kano

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Tasuku MatsuyamaDepartment of Emergency Medicine, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan.ORCID 0000-0003-4068-0306
Yuki YasutakeEmergency and Critical Care Center, Kagoshima City Hospital, Kagoshima 890-8760, Japan.
Daichi InabaEmergency and Critical Care Center, Kagoshima City Hospital, Kagoshima 890-8760, Japan.
Hideaki YoshiharaEmergency and Critical Care Center, Kagoshima City Hospital, Kagoshima 890-8760, Japan.
Keisuke BandoEmergency and Critical Care Center, Sapporo City General Hospital, Sapporo 060-8604, Japan.
Toshihisa MatsuiEmergency and Critical Care Center, Sapporo City General Hospital, Sapporo 060-8604, Japan.
Masaki NagamaEmergency and Critical Care Center, Kagoshima City Hospital, Kagoshima 890-8760, Japan.
Hitoshi KanoEmergency and Critical Care Center, Kagoshima City Hospital, Kagoshima 890-8760, Japan.
Kagoshima City Hospital · JPSapporo City General Hospital · JPKyoto Prefectural University of Medicine · JP

Funding

Japan Society for the Promotion of Science 21K16576
6 · The paper itself

Abstract

backgroundNIRO-Pulse is a novel mode of near-infrared spectroscopy that can be used to visually evaluate cerebral perfusion during cardiopulmonary resuscitation (CPR), providing real-time feedback as to the quality of the CPR. The aim of this report was to describe the several representative cases of NIRO-Pulse for physiological monitoring during CPR.

methodsWe present several cases from out-of-hospital cardiac arrest (OHCA) patients for whom NIRO-Pulse was attached to the forehead after hospital arrival. Patients were subjected to continuous brain monitoring during CPR using NIRO-Pulse, which allows for the visualisation of ΔHb (Hb pulsation). NIRO-Pulse is capable of simultaneously measuring and displaying cerebral tissue oxygen saturation (SctO2) and Hb pulsation, providing real-time feedback during CPR in the form of physiological indicators, and assessing changes in SctO2 throughout the CPR procedure by post-mortem analysis.

resultsWe observed several representative cases that provided the following insights: (1) SctO2 increased after a change in the quality of chest compression, (2) SctO2 decreased during the ventilation phase of synchronised CPR, (3) SctO2 decreased during the interruption of chest compressions for the preparation of defibrillation, and (4) SctO2 gradually and continuously increased after return of spontaneous circulation.

conclusionDisplaying Hb pulsation in conjunction with SctO2 during CPR may be helpful for evaluating the quality of and patient responsiveness to CPR. Further studies investigating the association between the use of NIRO-Pulse during CPR and subsequent outcomes should be conducted.

Indexed as

near-infrared spectroscopyout-of-hospital cardiac arrestphysiological monitoring

Identifiers

PMID35407626
PMCPMC8999562
OpenAlexW4223521838

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.