Novel Mode of Near-Infrared Spectroscopy as a Continuous Cerebral Physiological Monitoring Device during Cardiopulmonary Resuscitation: Four Case Reports.
Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Key physiological indicators and technological trends in physiology-directed cardiopulmonary resuscitation: A narrative review.Resuscitation plus · 2026Review
- Cerebral oxygen monitoring during out-of-hospital cardiac arrest: A scoping review.Resuscitation plus · 2025Review
- Pulse check accuracy in pediatrics during resuscitation: a systematic review.Resuscitation plus · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundNIRO-Pulse is a novel mode of near-infrared spectroscopy that can be used to visually evaluate cerebral perfusion during cardiopulmonary resuscitation (CPR), providing real-time feedback as to the quality of the CPR. The aim of this report was to describe the several representative cases of NIRO-Pulse for physiological monitoring during CPR.
methodsWe present several cases from out-of-hospital cardiac arrest (OHCA) patients for whom NIRO-Pulse was attached to the forehead after hospital arrival. Patients were subjected to continuous brain monitoring during CPR using NIRO-Pulse, which allows for the visualisation of ΔHb (Hb pulsation). NIRO-Pulse is capable of simultaneously measuring and displaying cerebral tissue oxygen saturation (SctO2) and Hb pulsation, providing real-time feedback during CPR in the form of physiological indicators, and assessing changes in SctO2 throughout the CPR procedure by post-mortem analysis.
resultsWe observed several representative cases that provided the following insights: (1) SctO2 increased after a change in the quality of chest compression, (2) SctO2 decreased during the ventilation phase of synchronised CPR, (3) SctO2 decreased during the interruption of chest compressions for the preparation of defibrillation, and (4) SctO2 gradually and continuously increased after return of spontaneous circulation.
conclusionDisplaying Hb pulsation in conjunction with SctO2 during CPR may be helpful for evaluating the quality of and patient responsiveness to CPR. Further studies investigating the association between the use of NIRO-Pulse during CPR and subsequent outcomes should be conducted.