Evidence map›Paper›PMID 35407537›Full record

ArticleJournal of clinical medicine2022

Cerebral Tissue Oxygen Saturation Is Enhanced in Patients following Transcatheter Aortic Valve Implantation: A Retrospective Study.

Götz Schmidt, Hannes Kreissl, Ursula Vigelius-Rauch, Emmanuel Schneck, Fabian Edinger, Holger Nef, Andreas Böning, Michael Sander, Christian Koch

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Götz SchmidtDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.ORCID 0000-0003-2346-4265
Hannes KreisslDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.
Ursula Vigelius-RauchDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.
Emmanuel SchneckDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.
Fabian EdingerDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.ORCID 0000-0002-7149-9705
Holger NefDepartment of Cardiology and Angiology, Justus Liebig University Giessen, Klinikstrasse 33, 35392 Giessen, Germany.
Andreas BöningDepartment of Cardiac and Vascular Surgery, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.
Michael SanderDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.ORCID 0000-0003-1677-3609
Christian KochDepartment of Anesthesiology, Operative Intensive Care Medicine and Pain Therapy, Justus Liebig University Giessen, Rudolf-Buchheim-Strasse 7, 35392 Giessen, Germany.ORCID 0000-0002-2655-7363
Justus-Liebig-Universität Gießen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement. The aim of this study was to evaluate whether a relevant alteration in cerebral tissue oxygen saturation (rSO2) could be detected following TAVI. Retrospective data analysis included 275 patients undergoing TAVI between October 2016 and December 2020. Overall, rSO2 significantly increased following TAVI (64.6 ± 10% vs. 68.1 ± 10%, p < 0.01). However, a significant rise was only observed in patients with a preoperative rSO2 < 60%. Of the hemodynamic confounders studied, hemoglobin, mean arterial pressure and blood pH were lowered, while central venous pressure and arterial partial pressure of carbon dioxide (PaCO2) were slightly elevated (PaCO2: 39 (36−43) mmHg vs. 42 (37−47) mmHg, p = 0.03; pH: 7.41 (7.3−7.4) vs. 7.36 (7.3−7.4), p < 0.01). Multivariate linear regression modeling identified only hemoglobin as a predictor of altered rSO2. Patients with a EuroScore II above 4% and an extended ICU stay were found to have lower rSO2, while no difference was observed in patients with postoperative delirium or between the implanted valve types. Further prospective studies that eliminate differences in potential confounding variables are necessary to confirm the rise in rSO2. Future research should provide more information on the value of cerebral oximetry for identifying high-risk patients who will require further clinical interventions in the setting of the TAVI procedure.

Indexed as

cardiac surgerycerebral oximetrynear-infrared spectroscopyNIRSTAVI

Identifiers

PMID35407537
PMCPMC8999949
OpenAlexW4220887273

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.