Evidence map›Paper›PMID 35407286›Full record

ArticleNanomaterials (Basel, Switzerland)2022

A Non-Resonant Piezoelectric-Electromagnetic-Triboelectric Hybrid Energy Harvester for Low-Frequency Human Motions.

Gang Tang, Zhen Wang, Xin Hu, Shaojie Wu, Bin Xu, Zhibiao Li, Xiaoxiao Yan, Fang Xu, Dandan Yuan, Peisheng Li and 2 more

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Gang TangJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Zhen WangJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Xin HuJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Shaojie WuJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Bin XuJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Zhibiao LiJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Xiaoxiao YanJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Fang XuJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Dandan YuanJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.
Peisheng LiJiangxi Province Key Laboratory of Precision Drive & Control, Nanchang Institute of Technology, Nanchang 330099, China.ORCID 0000-0002-9027-3381
Qiongfeng ShiDepartment of Electrical & Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.ORCID 0000-0002-5979-1420
Chengkuo LeeDepartment of Electrical & Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore.ORCID 0000-0002-8886-3649

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the rapid development of wireless communication and micro-power technologies, smart wearable devices with various functionalities appear more and more in our daily lives. Nevertheless, they normally possess short battery life and need to be recharged with external power sources with a long charging time, which seriously affects the user experience. To help extend the battery life or even replace it, a non-resonant piezoelectric-electromagnetic-triboelectric hybrid energy harvester is presented to effectively harvest energy from low-frequency human motions. In the designed structure, a moving magnet is used to simultaneously excite the three integrated energy collection units (i.e., piezoelectric, electromagnetic, and triboelectric) with a synergistic effect, such that the overall output power and energy-harvesting efficiency of the hybrid device can be greatly improved under various excitations. The experimental results show that with a vibration frequency of 4 Hz and a displacement of 200 mm, the hybrid energy harvester obtains a maximum output power of 26.17 mW at 70 kΩ for one piezoelectric generator (PEG) unit, 87.1 mW at 500 Ω for one electromagnetic generator (EMG) unit, and 63 μW at 140 MΩ for one triboelectric nanogenerator (TENG) unit, respectively. Then, the generated outputs are adopted for capacitor charging, which reveals that the performance of the three-unit integration is remarkably stronger than that of individual units. Finally, the practical energy-harvesting experiments conducted on various body parts such as wrist, calf, hand, and waist indicate that the proposed hybrid energy harvester has promising application potential in constructing a self-powered wearable system as the sustainable power source.

Indexed as

electromagnetichybridpiezoelectricself-poweredtriboelectric

Identifiers

PMID35407286
PMCPMC9000779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.