ArticleCancers2022
The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility.
Article in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 12 citations in OpenAlex.
- Helium pencil beam commissioning and beam modeling.Physics and imaging in radiation oncology · 2026Article
- Improved organs-of-interest dose reduction potential with intensity modulated proton therapy and breath-hold in mediastinal lymphoma.Physics and imaging in radiation oncology · 2026Article
- Comparison of gantry-less magnetic resonance guided proton therapy with photon therapy for hepatocellular carcinoma patients.Physics and imaging in radiation oncology · 2026Article
- Upright and supine particle therapy of lung cancer: A 4D dosimetric comparison.Medical physics · 2026Article
- Carbon ion radiotherapy and radiation-induced lung injury: clinical evidence, mechanistic insights, and future directions.Frontiers in oncology · 2026Review
- Towards ultra-fast treatments: large energy acceptance beam delivery systems and opportunities for proton beam therapy.Frontiers in oncology · 2026Review
- Dose assessment in moving targets and organs at risk during carbon ion therapy for pancreatic cancer with respiratory gating.Physics and imaging in radiation oncology · 2025Article
- Imaging lung tumor motion using integrated-mode proton radiography-A phantom study towards tumor tracking in proton radiotherapy.Medical physics · 2025Article
- A review of the clinical introduction of 4D particle therapy research concepts.Physics and imaging in radiation oncology · 2024Review
- Parameter based 4D dose calculations for proton therapy.Physics and imaging in radiation oncology · 2023Article
- Patient Breathing Motion and Delivery Specifics Influencing the Robustness of a Proton Pancreas Irradiation.Cancers · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Motion amplitudes, in need of mitigation for moving targets irradiated with pulsed carbon ions and protons, were identified to guide the decision on treatment and motion mitigation strategy. Measurements with PinPoint ionisation chambers positioned in an anthropomorphic breathing phantom were acquired to investigate different tumour motion scenarios, including rib and lung movements. The effect of beam delivery dynamics and spot characteristics was considered. The dose in the tumour centre was deteriorated up to 10% for carbon ions but only up to 5% for protons. Dose deviations in the penumbra increased by a factor of two when comparing carbon ions to protons, ranging from 2 to 30% for an increasing motion amplitude that was strongly dependent on the beam intensity. Layer rescanning was able to diminish the dose distortion caused by tumour motion, but an increase in spot size could reduce it even further to 5% within the target and 10% at the penumbra. An increased need for motion mitigation of carbon ions compared to protons was identified to assure target coverage and sparing of adjacent organs at risk in the penumbra region and outside the target. For the clinical implementation of moving target treatments at a synchrotron-based particle facility complex, time dependencies needed to be considered.