Evidence map›Paper›PMID 35405064›Full record

ArticleJournal of audiology & otology2022

Objective Comparison of Benefits Derived From Contralateral Routing of Signal Hearing Aid and Bone Conduction Device in Noisy Surroundings in Patients With Single-Sided Deafness.

Kapil Sikka, Rijendra Yogal, Alok Thakar, Rakesh Kumar, Tanvi Chaudhary, Mao Bhartiya, Hitesh Verma, Sonam Sharma, Chirom Amit Singh

Open access · diamondAbstract read
In one paragraph

Article in Journal of audiology & otology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Diverse interactions ofFrontiers in tuberculosis · 2024
    Review
  2. [Intervention effects of bone conduction hearing aids in patients with single-sided deafness and asymmetric hearing loss].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Kapil SikkaDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Rijendra YogalDepartment of Otorhinolaryngology & Head and Neck Surgery, Bhaktapur Cancer Hospital, Bhaktapur, Nepal.
Alok ThakarDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Rakesh KumarDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Tanvi ChaudharyDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Mao BhartiyaDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Hitesh VermaDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Sonam SharmaDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
Chirom Amit SinghDepartment of Otorhinolaryngology & Head and Neck Surgery, All India Institute of Medical Sciences, New Delhi, India.
All India Institute of Medical Sciences · INBhaktapur Cancer Hospital · NP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesSingle-sided deafness (SSD) leads to non-participation of the diseased ear in generating adequate auditory input, which results in poor speech discrimination in noisy surroundings. The present study objectively compared the audiological benefits rendered by contralateral routing of signal (CROS) hearing aid and bone conduction device (BCD) in patients with SSD >70 dB HL using the modified hearing in noise test (HINT). MATERIALS AND

methodsPatients with SSD >70 dB HL in poor and clinically normal hearing in the better ear were enrolled. Patients aged <18 or >70 years, with a history of neurological insult or ear infection in the last 3 months, mental retardation, psychiatric or developmental disorders, and diabetes were excluded. Modified HINT was performed with the affected ear unaided, aided with CROS hearing aid, and with BCD, generating three groups. Noise signal was presented at a fixed intensity of 65 dB at the neutral position in the center and speech signal was presented to either ear sequentially. The test was repeated with the speech signal fixed at the neutral position and the noise signal presented to either ear.

resultsBCD led to a better signal-to-noise ratio (SNR) than CROS hearing aid in all situations except when noise was centralized and speech was presented to the affected ear.

conclusionsA benefit was observed when auditory rehabilitation was used for the affected ear as demonstrated by better SNR scores. The results showed that BCD performed better than CROS hearing aid.

Indexed as

Hearing in noise testRehabilitationSignal to noise ratioUnilateral hearing loss

Identifiers

PMID35405064
PMCPMC9597271
OpenAlexW4223487193

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.