Evidence map›Paper›PMID 35404438›Full record

ArticleTranslational vision science & technology2022

Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva.

Kenichi Nakamura, Tomokazu Fujimoto, Miho Okada, Kentaro Maki, Atsushi Shimazaki, Masatomo Kato, Toshihiro Inoue

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Recent Advancements in Glaucoma Surgery-A Review.Bioengineering (Basel, Switzerland) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Kenichi NakamuraDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Tomokazu FujimotoDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Miho OkadaPharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan.
Kentaro MakiPharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan.
Atsushi ShimazakiPharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan.
Masatomo KatoPharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan.
Toshihiro InoueDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Santen (Japan) · JPKumamoto University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate tissue reactivity to, and the stability of, glaucoma drainage device materials placed under rabbit conjunctiva in vivo. Methods: Disks (diameter, 3 mm; thickness, ∼0.3 mm) fabricated from poly(styrene-block-isobutylene-block-styrene) (SIBS), silicone, stainless-steel, or glutaraldehyde cross-linked collagen (GACLC) were inserted under rabbit conjunctiva. Conjunctival and scleral sections obtained at 4, 8, and 12 weeks after surgery were immunostained for α-smooth muscle actin (SMA). The ratio of the maximum thickness of the α-SMA-positive conjunctiva to the scleral thickness (α-SMA/S ratio) was calculated. The in vivo stability of the drainage devices at 12 weeks after insertion was evaluated. Results: The mean α-SMA/S ratios of the SIBS and silicone groups were lower than that of the stainless-steel group at 4 weeks after surgery (P < 0.05), and that of the SIBS group was lower than that of the GACLC group (P < 0.05). The ratios at 8 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.01). The ratios at 12 weeks after surgery were lower in the SIBS and silicone groups than in the GACLC group (P < 0.05). The surface areas of GACLC disks explanted from conjunctivae were significantly lower than that of intact disks (P < 0.01). Conclusions: SIBS and silicon were highly biostable and exhibited less tissue reactivity than GACLC in vivo. Translational Relevance: Comparisons of materials using animal models can predict the clinical stability and safety of such materials in humans.

Indexed as

Glaucoma Drainage ImplantsAnimalsConjunctivaRabbitsSiliconesSteelStyreneSiliconesSteelStyrene

Identifiers

PMID35404438
PMCPMC9012888
OpenAlexW4223580232

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390