ArticleCureus2022
Evaluation of Patient Satisfaction and Clinical Efficacy of Using Blood Glucose Meters Featuring Color-Coded Indicators in Patients With Type 1 Diabetes: An Observational Hospital-Based Study.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Because of the difficulties in interpreting the level of blood glucose using the traditional numeric glucometers, the blood glucose meters featuring color-coded range indicators (CRI) offered a simple way to understand and interpret blood glucose readings. Therefore, this study aimed to assess glucose monitoring satisfaction (GMS) and clinical efficacy of blood glucose meters featuring color-coded in patients with Type 1 Diabetes (T1DM) in Saudi Arabia. Methods T1DM patients who switched to color-coded Medisafe Fit Smile glucometer were included in this study. Demographic data, clinical characteristics, glycemic parameters were collected. A trained interviewer collected the GMS survey at baseline and 12 weeks. At the end of the study, patient-reported satisfaction with the Medisafe Fit Smile color-coded features (MSCF) survey was collected. Results This study included 62 T1DM patients with a mean age of 17.8 (±3.1), and the majority had three or more confirmed hypoglycemic episodes per month. Compared to baseline data, we showed a significant improvement in the mean hemoglobin A1C level (8.43 [±1.2] versus 8.36 [±1.1], p<0.001), with a significantly lower frequency of hypoglycemic episodes (2.74 [±1.1] versus 2.0 [±0.78], p<0.001) after 12 weeks of using glucometer featuring CRI. Most importantly, significant improvements in the GMS survey subdomains of openness (p<0.001), emotional burden (p<0.001), behavioral burden (p<0.001), but not trust (p=0.71) were detected at the end of the study with a significantly higher total GMS survey of 4.33 (±0.13) after using blood glucose meters featuring CRI compared to the lower score of 2.84 (±0.22) at baseline (p<0.001). Furthermore, patient satisfaction with the MSCF survey revealed evidence of satisfaction among the TIDM patients at the end of the study. Conclusion The current study confirmed that individuals with T1DM may benefit from blood glucose meters featuring CRI device exposure. Also, using a glucometer featuring CRI was associated with a high level of satisfaction with blood glucose measures and significant improvement in the glycemic parameters. However, definitely, further studies are needed to confirm whether the long-term use of the CRI-based blood glucose meters will produce improved results in the GMS survey.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.