ArticleBone & joint research2022

Does tibial design modification improve implant stability for total knee arthroplasty? An experimental cadaver study.

Sebastian Jaeger, Marvin Eissler, Martin Schwarze, Mareike Schonhoff, J Philippe Kretzer, Rudi G Bitsch

Open access · goldAbstract read
In one paragraph

Article in Bone & joint research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Sebastian JaegerLaboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID 0000-0001-7687-6904
Marvin EisslerDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.ORCID 0000-0001-9567-841X
Martin SchwarzeLaboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Mareike SchonhoffLaboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.
J Philippe KretzerLaboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Rudi G BitschLaboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Heidelberg University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsOne of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined.

methodsA tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD).

resultsThe BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups.

conclusionFrom a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article:

Indexed as

Aseptic looseningAttuneAttune S+bone marrowbone mineral density (BMD)Cement debondingCement pocketsflexionImplant stabilitymetalRevision surgeriesstable fixationtibiatibial componentstotal knee arthroplasty

Identifiers

PMID35400170
PMCPMC9057524
OpenAlexW4223458344

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.