ArticleScientific reports2022
Accuracy of the doses computed by the Eclipse treatment planning system near and inside metal elements.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 11 citations in OpenAlex.
- Dosimetric comparison of scanned proton therapy and volumetric modulated arc therapy in isodose-prescribed stereotactic body radiotherapy for lung cancer.Journal of radiation research · 2026Article
- Dose calculation accuracy with extended CT scales near metal: phantom-patient evaluation using a beam-metal overlap metric.Radiation oncology (London, England) · 2026Article
- Article
- Residual range-based quenching correction for Gafchromic EBT3 film in proton therapy patient-specific QA.Journal of applied clinical medical physics · 2025Article
- The accuracy of Eclipse AXB and AAA dose algorithms with dental amalgam.Physical and engineering sciences in medicine · 2024Article
- Metallic Artifact Reduction in Midfacial CT Scans Using Patient-Specific Polymer Implants Enhances Image Quality.Journal of personalized medicine · 2023Article
- Dose difference between anisotropic analytical algorithm (AAA) and Acuros XB (AXB) caused by target's air content for volumetric modulated arc therapy of head and neck cancer.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Metal artefacts degrade clinical image quality which decreases the confidence of using computed tomography (CT) for the delineation of key structures for treatment planning and leads to dose errors in affected areas. In this work, we investigated accuracy of doses computed by the Eclipse treatment planning system near and inside metallic elements for two different computation algorithms. An impact of CT metal artefact reduction methods on the resulting calculated doses has also been assessed. A water phantom including Gafchromic film and metal inserts was irradiated (max dose 5 Gy) using a 6 MV photon beam. Three materials were tested: titanium, alloy 600, and tungsten. The phantom CT images were obtained with the pseudo-monoenergetic reconstruction (PMR) and the iterative metal artefact reduction (iMAR). Image sets were used for dose calculation using an Eclipse treatment planning station (TPS). Monte Carlo (MC) simulations were used to predict the true dose distribution in the phantom allowing for comparison with doses measured by film and calculated by TPS. Measured and simulated percentage depth doses (PDDs) were not statistically different (p > 0.618). Regional differences were observed at edges of metallic objects (max 8% difference). However, PDDs simulated with and without film were statistically different (p < 0.002). PDDs calculated by the Acuros XB algorithm based on the dose-to-medium approach best matched the MC reference regardless of the CT reconstruction methods and inserts used (p > 0.078). PDDs obtained using other algorithms significantly differ from the MC values (p < 0.011). The Acuros XB algorithm with a dose-to-medium approach provides reliable dose calculation in all metal regions when using the Varian system. The inability of the AAA algorithm to model backscatter dose significantly limits its clinical application in the presence of metal. No significant impact on the dose calculation was found for a range of metal artefact reduction strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials