Evidence map›Paper›PMID 35394654›Full record

ArticleAdvanced healthcare materials2022

Continuous Microfiber Wire Mandrel-Less Biofabrication for Soft Tissue Engineering Applications.

Arianna Adamo, Joseph G Bartolacci, Drake D Pedersen, Marco G Traina, Seungil Kim, Antonio Pantano, Giulio Ghersi, Simon C Watkins, William R Wagner, Stephen F Badylak and 1 more

Open access · hybridAbstract read
In one paragraph

Article in Advanced healthcare materials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 2 countries.

Arianna AdamoMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Joseph G BartolacciMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Drake D PedersenMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Marco G TrainaMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Seungil KimMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Antonio PantanoDepartment of Engineering, University of Palermo, Palermo, 90133, Italy.
Giulio GhersiDepartment of Biological, Chemical and Pharmaceutical Sciences and Technologies, Palermo, 90123, Italy.
Simon C WatkinsDepartment of Cell Biology, University of Pittsburgh School of Medicine, Pittsburgh, PA, 15213, USA.
William R WagnerMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Stephen F BadylakMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.
Antonio D'AmoreMcGowan Institute for Regenerative Medicine, Pittsburgh, PA, 15219, USA.ORCID 0000-0002-3151-3170
University of Pittsburgh · USMcGowan Institute for Regenerative Medicine · USUniversity of Palermo · ITRi.MED · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Suture materials are the most common bioimplants in surgical and clinical practice, playing a crucial role in wound healing and tendon and ligament repair. Despite the assortment available on the market, sutures are still affected by significant disadvantages, including failure in mimicking the mechanical properties of the tissue, excessive fibrosis, and inflammation. This study introduces a mandrel-less electrodeposition apparatus to fabricate continuous microfiber wires of indefinite length. The mandrel-less biofabrication produces wires, potentially used as medical fibers, with different microfiber bundles, that imitate the hierarchical organization of native tissues, and tailored mechanical properties. Microfiber wire morphology and mechanical properties are characterized by scanning electron microscopy, digital image processing, and uniaxial tensile test. Wires are tested in vitro on monocyte/macrophage stimulation and in vivo on a rat surgical wound model. The wires produced by mandrel-less deposition show an increased M2 macrophage phenotype in vitro. The in vivo assessment demonstrates that microfiber wires, compared to the medical fibers currently used, reduce pro-inflammatory macrophage response and preserve their mechanical properties after 30 days of use. These results make this microfiber wire an ideal candidate as a suture material for soft tissue surgery, suggesting a crucial role of microarchitecture in more favorable host response.

Indexed as

SuturesTissue EngineeringAnimalsRatsTendonsTensile StrengthWound Healingbiofabricationbiomaterials host responseinflammationmacrophagic responsesmedical textiles

Identifiers

PMID35394654
PMCPMC11469050
OpenAlexW4224290374

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.