ArticleMagnetic resonance in medicine2022
SPRING-RIO TSE: 2D T
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- A retraced spiral strategy with semi-automatic deblurring for volumetric thermometry.Magnetic resonance in medicine · 2025Article
- Three-dimensional high-isotropic-resolution MR fingerprinting optimized for 0.55 T.Magnetic resonance in medicine · 2025Article
- Variable-flip-angle 3D spiral-in-out turbo spin-echo imaging using concomitant gradient compensation and echo reordering at 0.55 T.Magnetic resonance in medicine · 2025Article
- MRI denoising with a non-blind deep complex-valued convolutional neural network.NMR in biomedicine · 2025Article
- Concomitant magnetic-field compensation for 2D spiral-ring turbo spin-echo imaging at 0.55T and 1.5T.Magnetic resonance in medicine · 2023Article
- Concomitant field compensation of spiral turbo spin-echo at 0.55 T.Magma (New York, N.Y.) · 2023Article
- SPRING-RIO TSE: 2D TMagnetic resonance in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo develop a new approach to 2D turbo spin -echo (TSE) imaging using annular spiral rings with a retraced in/out trajectory, dubbed "SPRING-RIO TSE", for fast T
methodsA long spiral trajectory was split into annular segmentations that were then incorporated into a 2D TSE acquisition module to fully exploit the sampling efficiency of spiral rings. A retraced in/out trajectory strategy coupled with spiral-ring TSE was introduced to increase SNR, mitigate T
resultsSimulation and phantom studies demonstrated the performance of the proposed SPRING-RIO TSE pulses sequence, as well as that of trajectory correction and off-resonance correction. Volunteer data showed that the proposed method achieves high-quality 2D T
conclusion2D T
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.