ArticleVeterinary surgery : VS2022
Compression generated by cortical screws in an artificial bone model of an equine medial femoral condylar cyst.
Article in Veterinary surgery : VS, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Treatment Comparison for Medial Femoral Condyle Subchondral Cystic Lesions and Prognosis in Yearling Thoroughbred Racehorse Prospects.Animals : an open access journal from MDPI · 2024Article
- Compression generated by cortical screws in an artificial bone model of an equine medial femoral condylar cyst.Veterinary surgery : VS · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
objectiveDetermine compression generated by lag and neutral screws over 12 h using two bone analogs. STUDY
designExperimental study. SAMPLE POPULATION: Bone analogs were made of composite synthetic bone (CSB) or three-dimensional printed polylactic acid (PLA). Analogs had a 2 mm exterior shell with a 10 mm thick internal layer of open-cell material.
methodsBone analogs were opposed, making a 4-sided box with open ends. A central channel contained the sensor and the screws passed through it to engage both paired analogs. Four screw/analog conditions were tested: neutral and lag screw with bicortical engagement, neutral and lag screw with unicortical engagement. All screws were tightened to 2 Nm torque and compression values recorded at 0, 0.5, 1, 2, 6, and 12 h (six trials per condition). Medians were compared across groups for statistical significance.
resultsThere was no difference in median compression between lag and neutral bicortical screws. For PLA, greater median compression was generated by neutral (median 437 N) and lag (median 379 N) bicortical screws compared to neutral unicortical screws (median 208 N, p < .001); lag bicortical screws generated greater median compression than lag unicortical screws (median 265 N, p = .012). For CSB, lag bicortical screws (median 293 N) generated greater median compression than neutral unicortical screws (median 228 N, p = .008).
conclusionLag and neutral screws generated similar compression. Bicortical screws had higher median compression than unicortical screws in bone analogs. CLINICAL SIGNIFICANCE: Neutral screws generate compression in cancellous bone analogs that can be increased with bicortical bone engagement.