ArticleComputational and mathematical methods in medicine2022
Feasibility of Constructing an Automatic Meniscus Injury Detection Model Based on Dual-Mode Magnetic Resonance Imaging (MRI) Radiomics of the Knee Joint.
Article in Computational and mathematical methods in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Diagnosis of knee meniscal injuries using artificial intelligence: A systematic review and meta-analysis of diagnostic performance.PloS one · 2025Pooled it
- Radiomics signature of osteoarthritis: Current status and perspective.Journal of orthopaedic translation · 2024Review
- Retracted: Feasibility of Constructing an Automatic Meniscus Injury Detection Model Based on Dual-Mode Magnetic Resonance Imaging (MRI) Radiomics of the Knee Joint.Computational and mathematical methods in medicine · 2023Article
- The Potential and Emerging Role of Quantitative Imaging Biomarkers for Cancer Characterization.Cancers · 2022Review
Corrections and comments
- Retraction · 2023-09-27Concerns/Issues about Data · Concerns/Issues about Results and/or Conclusions · Concerns/Issues about Referencing/Attributions · Concerns/Issues about Peer Review · Investigation by Journal/Publisher · Investigation by Third Party · Paper Mill · Computer-Aided Content or Computer-Generated Content · Unreliable Results and/or Conclusions · · See also: https://pubpeer.com/publications/DA768058EF8F313ABB8BE6CE565CC4
- Retracted
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To explore the feasibility of automatically detecting the degree of meniscus injury by radiomics fusion of dual-mode magnetic resonance imaging (MRI) features of sagittal and coronal planes of the knee joint. Methods: This retrospective study included 164 arthroscopically confirmed meniscus injuries in 152 patients admitted to the Department of Orthopaedics of our hospital from July 2018 to March 2021. A total of 1316-dimensional radiomics signatures were extracted from single-mode sagittal and coronal plane images of menisci, respectively. Then, the sagittal and coronal plane features were fused to form a dual-mode joint feature group with a total of 2632-dimensional radiomics signatures. The minimum redundancy maximum relevance (mRMR) algorithm and the least absolute shrinkage and selection operator (LASSO) regression were used to select features and generate optimal radiomics signatures. The single-mode sagittal plane feature model (Model 1), single-mode coronal plane feature model (Model 2), and the combined sagittal and coronal plane feature model (Model 3) performance were tested by receiver operating characteristic (ROC) curves and Delong test. The calibration curve test was used to verify the reliability of radiomics signatures of the three models. Results: The average intra- and interobserver intraclass correlation coefficients (ICCs) of the most significant 8-dimensional radiomics signatures of Model 1 and Model 2 were 0.935 (range 0.832-0.998) and 0.928 (range 0.845-0.998), respectively. All the three models had good detection performance; Model 3 had the most significant performance (the areas under the curve (AUCs) of training, and validation sets were 0.947 and 0.923, respectively), which was superior to Model 1 (AUCs of training set and validation set were 0.889 and 0.876, respectively) and Model 2 (AUCs of training set and validation set were 0.831 and 0.851, respectively). The detection probability of training and validation sets in the three models was highly consistent with the actual clinical probability. Conclusions: It is feasible to establish a model for automatic detection of meniscus damage by means of radiomics. The detection performance of the dual-mode knee MRI model is better than that of any single-mode model, showing potent feature analysis ability and outstanding detection performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.