Evidence map›Paper›PMID 35392008›Full record

ArticleNagoya journal of medical science2022

Reliability and validity of lower limb joint range of motion measurements using a smartphone.

Yousuke Miyachi, Morihiro Ito, Kunihiro Furuta, Rua Ban, Shuntaro Hanamura, Mitsuhiro Kamiya

Abstract read
In one paragraph

Article in Nagoya journal of medical science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yousuke MiyachiGraduate School of Life and Health Sciences, Chubu University, Kasugai, Japan.
Morihiro ItoGraduate School of Life and Health Sciences, Chubu University, Kasugai, Japan.
Kunihiro FurutaDepartment of Rehabilitation, Sikatsu Orthopedic Hospital, Kitanagoya, Japan.
Rua BanDepartment of Rehabilitation, Asahi Hospital, Kasugai, Japan.
Shuntaro HanamuraDepartment of Orthopedic Surgery, Asahi Hospital, Kasugai, Japan.
Mitsuhiro KamiyaDepartment of Orthopedic Surgery, Asahi Hospital, Kasugai, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to examine the reliability and validity of using a smartphone to measure the multi-joint range of motion of the lower limbs. We measured the straight leg raise angle, ankle dorsiflexion angle, and hip internal rotation angle in each of the 40 lower extremities of 20 healthy adults. Measurements were compared between a conventional method using a goniometer and a smartphone application method. The intraclass correlation coefficient (ICC) was used to evaluate the reliability of each smartphone measurement, and Bland-Altman analysis was used to examine measurement errors. The criterion-related validity of the two methods was also examined. Intra-rater reliability (ICC 0.668-0.939) was substantial to almost perfect, with no systematic errors found for all items, and the standard errors of measurement were acceptable. Inter-rater reliability (ICC 0.701-0.936) was also substantial to almost perfect, but the straight leg raise angle and hip internal rotation angle showed fixation errors. For these two measurements, with more than one examiner, the limit of agreement of error needs to be considered. No systematic errors were found in the ankle dorsiflexion angle, and the standard error of measurement was within the acceptable range. A moderate to strong correlation (r = 0.626-0.915) was found between the conventional and smartphone methods, demonstrating good criterion-related validity. However, in the ankle dorsiflexion angle measurements, the reliability and validity were shown to be lower than the other two items. This suggested the necessity of changing the measurement conditions in order to use the ankle dorsiflexion angle in clinical practice.

Indexed as

Mobile ApplicationsSmartphoneAdultHumansLower ExtremityRange of Motion, ArticularReproducibility of Resultsmeasurementrange of motionreliabilitysmartphonevalidity

Identifiers

PMID35392008
PMCPMC8971043

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.