Article3D printing in medicine2022
Comparison of fluid dynamics changes due to physical activity in 3D printed patient specific coronary phantoms with the Windkessel equivalent model of coronary flow.
Article in 3D printing in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Surgical treatment of giant diagonal branch aneurysms accompanied by obstructive coronary artery disease with guidance from 3D printed models: a case report.BMC cardiovascular disorders · 2026Article
- Integrated multidisciplinary approach to aneurysm hemodynamic analysis: numerical simulation,Frontiers in bioengineering and biotechnology · 2025Review
- Influence of the orientation of constructed blood vessels during the 3D printing on the measurement of the pseudo-oxygen saturation of an artificial blood substitute using conventional oxygen sensors: a test series.3D printing in medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background3D printing (3DP) used to replicate the geometry of normal and abnormal vascular pathologies has been demonstrated in many publications; however, reproduction of hemodynamic changes due to physical activities, such as rest versus moderate exercise, need to be investigated. We developed a new design for patient specific coronary phantoms, which allow adjustable physiological variables such as coronary distal resistance and coronary compliance in patients with coronary artery disease. The new design was tested in precise benchtop experiments and compared with a theoretical Windkessel electrical circuit equivalent, that models coronary flow and pressure using arterial resistance and compliance.
methodsFive phantoms from patients who underwent clinically indicated elective invasive coronary angiography were built from CCTA scans using multi-material 3D printing. Each phantom was used in a controlled flow system where patient specific flow conditions were simulated by a programmable cardiac pump. To simulate the arteriole and capillary beds flow resistance and the compliance for various physical activities, we designed a three-chamber outlet system which controls the outflow dynamics of each coronary tree. Benchtop pressure measurements were recorded using sensors embedded in each of the main coronary arteries. Using the Windkessel model, patient specific flow equivalent electrical circuit models were designed for each coronary tree branch, and flow in each artery was determined for known inflow conditions. Local flow resistances were calculated through Poiseuille's Law derived from the radii and lengths of the coronary arteries using CT angiography based multi-planar reconstructions. The coronary stenosis flow rates from the benchtop and the electrical models were compared to the localized flow rates calculated from invasive pressure measurements recorded in the angio-suites.
resultsThe average Pearson correlations of the localized flow rates at the location of the stenosis between each of the models (Benchtop/Electrical, Benchtop/Angio, Electrical/Angio) are 0.970, 0.981, and 0.958 respectively.
conclusions3D printed coronary phantoms can be used to replicate the human arterial anatomy as well as blood flow conditions. It displays high levels of correlation when compared to hemodynamics calculated in electrically-equivalent coronary Windkessel models as well as invasive angio-suite pressure measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.