Evidence map›Paper›PMID 35389117›Full record

Article3D printing in medicine2022

Comparison of fluid dynamics changes due to physical activity in 3D printed patient specific coronary phantoms with the Windkessel equivalent model of coronary flow.

Kelsey N Sommer, Mohammad Mahdi Shiraz Bhurwani, Vijay Iyer, Ciprian N Ionita

Open access · goldAbstract read
In one paragraph

Article in 3D printing in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Kelsey N SommerDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA. kelseyso@buffalo.edu.
Mohammad Mahdi Shiraz BhurwaniDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.
Vijay IyerUniversity at Buffalo Cardiology, University at Buffalo Jacobs School of Medicine, Buffalo, NY, USA.
Ciprian N IonitaDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.
University at Buffalo, State University of New York · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background3D printing (3DP) used to replicate the geometry of normal and abnormal vascular pathologies has been demonstrated in many publications; however, reproduction of hemodynamic changes due to physical activities, such as rest versus moderate exercise, need to be investigated. We developed a new design for patient specific coronary phantoms, which allow adjustable physiological variables such as coronary distal resistance and coronary compliance in patients with coronary artery disease. The new design was tested in precise benchtop experiments and compared with a theoretical Windkessel electrical circuit equivalent, that models coronary flow and pressure using arterial resistance and compliance.

methodsFive phantoms from patients who underwent clinically indicated elective invasive coronary angiography were built from CCTA scans using multi-material 3D printing. Each phantom was used in a controlled flow system where patient specific flow conditions were simulated by a programmable cardiac pump. To simulate the arteriole and capillary beds flow resistance and the compliance for various physical activities, we designed a three-chamber outlet system which controls the outflow dynamics of each coronary tree. Benchtop pressure measurements were recorded using sensors embedded in each of the main coronary arteries. Using the Windkessel model, patient specific flow equivalent electrical circuit models were designed for each coronary tree branch, and flow in each artery was determined for known inflow conditions. Local flow resistances were calculated through Poiseuille's Law derived from the radii and lengths of the coronary arteries using CT angiography based multi-planar reconstructions. The coronary stenosis flow rates from the benchtop and the electrical models were compared to the localized flow rates calculated from invasive pressure measurements recorded in the angio-suites.

resultsThe average Pearson correlations of the localized flow rates at the location of the stenosis between each of the models (Benchtop/Electrical, Benchtop/Angio, Electrical/Angio) are 0.970, 0.981, and 0.958 respectively.

conclusions3D printed coronary phantoms can be used to replicate the human arterial anatomy as well as blood flow conditions. It displays high levels of correlation when compared to hemodynamics calculated in electrically-equivalent coronary Windkessel models as well as invasive angio-suite pressure measurements.

Indexed as

3D PrintingCoronary Artery DiseaseCoronary CTAWindkessel model

Identifiers

PMID35389117
PMCPMC8988414
OpenAlexW4223492616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.