Evidence map›Paper›PMID 35388023›Full record

ArticleScientific reports2022

Comparison of device-based therapy options for heart failure with preserved ejection fraction: a simulation study.

Marcus Granegger, Christoph Gross, David Siemer, Andreas Escher, Sigrid Sandner, Martin Schweiger, Günther Laufer, Daniel Zimpfer

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Marcus GraneggerDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria. marcus.granegger@meduniwien.ac.at.
Christoph GrossDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria.
David SiemerPediatric Cardiovascular Surgery, University Children's Hospital Zurich, Zurich, Switzerland.
Andreas EscherDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria.
Sigrid SandnerDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria.
Martin SchweigerPediatric Cardiovascular Surgery, University Children's Hospital Zurich, Zurich, Switzerland.
Günther LauferDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria.
Daniel ZimpferDepartment of Cardiac Surgery, Medical University of Vienna, Währingergürtel 18-20, 1090, Vienna, Austria.
Medical University of Vienna · ATUniversity Children's Hospital Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Successful therapy of heart failure with preserved ejection fraction (HFpEF) remains a major unmet clinical need. Device-based treatment approaches include the interatrial shunt device (IASD), conventional assist devices pumping blood from the left ventricle (LV-VAD) or the left atrium (LA-VAD) towards the aorta, and a valveless pulsatile assist device with a single cannula operating in co-pulsation with the native heart (CoPulse). Hemodynamics of two HFpEF subgroups during rest and exercise condition were translated into a lumped parameter model of the cardiovascular system. The numerical model was applied to assess the hemodynamic effect of each of the four device-based therapies. All four therapy options show a reduction in left atrial pressure during rest and exercise and in both subgroups (> 20%). IASDs concomitantly reduce cardiac output (CO) and shift the hemodynamic overload towards the pulmonary circulation. All three mechanical assist devices increase CO while reducing sympathetic activity. LV-VADs reduce end-systolic volume, indicating a high risk for suction events. The heterogeneity of the HFpEF population requires an individualized therapy approach based on the underlying hemodynamics. Whereas phenotypes with preserved CO may benefit most from an IASD device, HFpEF patients with reduced CO may be candidates for mechanical assist devices.

Indexed as

Heart FailureAtrial PressureHeart AtriaHemodynamicsHumansStroke VolumeVentricular Function, Left

Identifiers

PMID35388023
PMCPMC8987034
OpenAlexW4223468315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.