Evidence map›Paper›PMID 35387701›Full record

Trial reportInfection control and hospital epidemiology2023

Quantitative fit-test concordance of a pair of similar-fit 3M Aura respirator models, 3M 9320A+ and 3M 1870+: A randomized crossover study.

Daryl Lindsay Williams, Benjamin Kave, Fiona Begg, Charles Bodas, Irene Ng

Open access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Infection control and hospital epidemiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Daryl Lindsay WilliamsDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville, Australia.ORCID 0000-0002-6987-5804
Benjamin KaveDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville, Australia.
Fiona BeggRespiratory Protection Program, Royal Melbourne Hospital, Parkville, Australia.ORCID 0000-0001-5456-7852
Charles BodasRespiratory Protection Program, Royal Melbourne Hospital, Parkville, Australia.ORCID 0000-0002-6533-7646
Irene NgDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville, Australia.ORCID 0000-0002-6632-5604
The Royal Melbourne Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveSome manufacturers provide information on similar-fit model pairings of filtering facepiece respirators (FFRs), suggesting that fit-test outcome of one model helps predict the other. This guidance may be useful during crisis capacity when FFR supplies and/or fit tests are constrained. The purpose of this study was to compare quantitative fit-test (QNFT) results and concordance between a pair of similar-fit 3M Aura FFRs: the 3M 9320A+ and 3M 1870+.

methodsAll participants completed online training and a QNFT with both respirators. The order of the respirator being examined first was randomly allocated. The outcomes included QNFT pass rate, concordance between the 2 models, overall and individual fit factors, and percentage of male and female participants who passed or failed the QNFT.

resultsWe recruited 1,000 participants (668 females and 332 males). The QNFT pass rate, overall fit factors, and individual fit factors were significantly higher for the 3M 9320A+ than the 3M 1870+ FFR. The concordance between the models was "fair" (κ coefficient, 0.38). Male participants who passed a QNFT with either of the FFRs had 96% chance of passing the QNFT for the alternate model. Female participants who passed the 3M 1870+ had 97% chance of passing the QNFT for the 3M 9320A+ model. However, ∼1 in 12 females who passed the QNFT for the 3M 9320A+ failed the QNFT for the 3M 1870+ FFR.

conclusionsSimilar-fit paired FFR models may provide a consequentially different level of respiratory protection, especially for women. Our findings are important for FFR stockpiling and fit-testing strategies, especially during crisis capacity.

Indexed as

EpilepsyOccupational ExposureRespiratory Protective DevicesCross-Over StudiesEquipment DesignFemaleHumansMaleVentilators, Mechanical

Identifiers

PMID35387701
PMCPMC9929707
OpenAlexW4225432601

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.