Evidence map›Paper›PMID 35387621›Full record

Trial reportBMC musculoskeletal disorders2022

Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach.

Yue Li, Long Chen, Yuzeng Liu, Hongtao Ding, Hongyi Lu, Aixing Pan, Xinuo Zhang, Yong Hai, Li Guan

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. A comparison of key performance metrics of major robotic platforms in spine surgery: a network meta-analysis of 14,462 screws.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Pooled it
  2. Pooled it
  3. Pooled it
  4. Comparison of major spine navigation platforms based on key performance metrics: a meta-analysis of 16,040 screws.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Pooled it
  5. Robotic-assisted fixation with cortical bone trajectory versus conventional pedicle trajectory for short-segment lumbar decompression and fusion surgery: a retrospective propensity score-matched cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Robot-assistedWorld journal of orthopedics · 2025
    Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. [History and trends of robot-assisted spine surgery].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yue Li *Department of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.ORCID http://orcid.org/0000-0001-6924-8969
Long Chen *Department of Orthopedics, Guangzhou Red Cross Hospital Affiliated To Jinan University, No. 396, Mid Tongfu Road, Haizhu District, Guangzhou, 510000, Guangdong, P. R. China.ORCID http://orcid.org/0000-0003-1333-0132
Yuzeng LiuDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China. beijingspine2010@163.com.ORCID http://orcid.org/0000-0003-2128-4594
Hongtao DingDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.
Hongyi LuDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.
Aixing PanDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.
Xinuo ZhangDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.
Yong HaiDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.ORCID http://orcid.org/0000-0002-7206-325X
Li GuanDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, GongTiNanLu 8#, Chaoyang District, Beijing, 100020, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the safety and accuracy of cortical bone trajectory screw placement between the robot-assisted and fluoroscopy-assisted approaches.

methodsThis retrospective study was conducted between November 2018 and June 2020, including 81 patients who underwent cortical bone trajectory (CBT) surgery for degenerative lumbar spine disease. CBT was performed by the same team of experienced surgeons. The patients were randomly divided into two groups-the fluoroscopy-assisted group (FA, 44 patients) and the robot-assisted group (RA, 37 patients). Robots for orthopedic surgery were used in the robot-assisted group, whereas conventional fluoroscopy-guided screw placement was used in the fluoroscopy-assisted group. The accuracy of screw placement and rate of superior facet joint violation were assessed using postoperative computed tomography (CT). The time of single screw placement, intraoperative blood loss, and radiation exposure to the surgical team were also recorded. The χ

resultsA total of 376 screws were inserted in 81 patients, including 172 screws in the robot-assisted group and 204 pedicle screws in the fluoroscopy-assisted group. Screw placement accuracy was higher in the RA group (160, 93%) than in the FA group (169, 83%) (P = 0.003). The RA group had a lower violation of the superior facet joint than the FA group. The number of screws reaching grade 0 in the RA group (58, 78%) was more than that in the FA group (56, 64%) (P = 0.041). Screw placement time was longer in the FA group (7.25 ± 0.84 min) than in the RA group (5.58 ± 1.22 min, P < 0.001). The FA group had more intraoperative bleeding (273.41 ± 118.20 ml) than the RA group (248.65 ± 97.53 ml, P = 0.313). The radiation time of the FA group (0.43 ± 0.07 min) was longer than the RA group (0.37 ± 0.10 min, P = 0.001). Furthermore, the overall learning curve tended to decrease.

conclusionsRobot-assisted screw placement improves screw placement accuracy, shortens screw placement time, effectively improves surgical safety and efficiency, and reduces radiation exposure to the surgical team. In addition, the learning curve of robot-assisted screw placement is smooth and easy to operate.

Indexed as

Pedicle ScrewsRoboticsRobotic Surgical ProceduresSpinal FusionSurgery, Computer-AssistedCortical BoneFluoroscopyHumansLumbar VertebraeRetrospective StudiesAccuracyCortical bone trajectoryFacet joint violationLearning curveRobot-Assisted

Identifiers

PMID35387621
PMCPMC8988323

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.