Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system.

Jian-Kuen Wu, Min-Chin Yu, Shih-Han Chen, Shu-Hsien Liao, Yu-Jen Wang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 1 country.

Jian-Kuen WuDivision of Radiation Oncology, Departments of Oncology, National Taiwan University Hospital, Taipei, Taiwan.
Min-Chin YuDepartment of Radiation Oncology, Taipei Medical University Hospital, Taipei, Taiwan.
Shih-Han ChenDepartment of Medical Imaging, National Taiwan University Cancer Center, Taipei, Taiwan.
Shu-Hsien LiaoInstitute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, Taiwan.
Yu-Jen WangDepartment of Radiation Oncology, Fu Jen Catholic University Hospital, New Taipei City, Taiwan.ORCID 0000-0001-5642-0352
Fu Jen Catholic University · TWNational Taiwan Normal University · TWNational Taiwan University · TWNational Taiwan University Hospital · TWTaipei Medical University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeImage-guided radiation therapy (IGRT) is used to precisely deliver radiation to a tumour to reduce the possible damage to the surrounding normal tissues. Clinics use various quality assurance (QA) equipment to ensure that the performance of the IGRT system meets the international standards set for the system. The objective of this study was to develop a low-cost and multipurpose module for evaluating image quality and dose.

methodsA multipurpose phantom was designed to meet the clinical requirements of high accuracy, easy setup, and calibration. The outer shell of the phantom was fabricated using acrylic. Three dimensional (3D) printing technology was used to fabricate inner slabs with the characteristics of high spatial resolution, low-contrast detectability, a 3D grid, and liquid-filled uniformity. All materials were compatible with magnetic resonance (MR). Computed tomography (CT) simulator and linear accelerator (LINAC) modules were developed and validated.

resultsThe uniformity slab filled with water is ideal for the assessment of Hounsfield units, whereas that filled with wax is suitable for consistency checks. The high-spatial-resolution slab enables measurements with a resolution up to 5 lp/cm. The low-contrast detectability slab contains rods of 5 different sizes that can be clearly visualised. These components meet the American College of Radiology (ACR) standards for QA of CT simulators and LINACs.

conclusionsThe multifunctional phantom module meets the ACR recommended QA guidelines and is suitable for both LINACs and CT-sim. Further measurements in an MR simulator and an MR linear accelerator (MR-LINAC) will be arranged in the future.

Indexed as

Radiotherapy, Image-GuidedHumansImage Processing, Computer-AssistedParticle AcceleratorsPhantoms, ImagingPrinting, Three-Dimensional

Identifiers

PMID35385553
PMCPMC8986000
OpenAlexW4226211084

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.