Trial reportBMC anesthesiology2022
Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study.
Trial report in BMC anesthesiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe third-generation streamlined liner of the pharynx airway (SLIPA-3G) is a new-generation supraglottic airway device (SAD) that is non-cuffed and disposable, with a sealing pressure that varies dynamically with the airway pressure. This study compared the SLIPA-3G with the laryngeal mask airway supreme (LMAS) in patients undergoing laparoscopic cholecystectomy.
methodsTwo hundred and twenty patients scheduled for laparoscopic cholecystectomy were randomly allocated to either the SLIPA-3G group or the LMAS group. Data were collected on the patients' hemodynamic parameters at different time points, ease of insertion, fiberoptic view, oropharyngeal leak pressure (OLP) at different time points and SAD-related complications.
resultsThe mean OLP immediately after device placement in the LMAS group was significantly higher than that of the SLIPA-3G group (31.34 ± 6.99 cmH
conclusionsThe SLIPA-3G and LMAS were associated with comparable OLPs, hemodynamic parameters, ease of insertion, fiberoptic views and complication rates when used during laparoscopic cholecystectomy. The SLIPA-3G can be used as an effective alternative to the LMAS in patients undergoing laparoscopic surgeries.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.