Evidence map›Paper›PMID 35381872›Full record

ArticleJournal of the Association for Research in Otolaryngology : JARO2022

Comparison of Responses to DCN vs. VCN Stimulation in a Mouse Model of the Auditory Brainstem Implant (ABI).

Stephen McInturff, Florent-Valéry Coen, Ariel E Hight, Osama Tarabichi, Vivek V Kanumuri, Nicolas Vachicouras, Stéphanie P Lacour, Daniel J Lee, M Christian Brown

Abstract readComparative Study
In one paragraph

Article in Journal of the Association for Research in Otolaryngology : JARO, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Origins of the Auditory Brainstem Response in Mice Using Source Localization of Topographic Multichannel EEG.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Stephen McInturffEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA. stephen_mcinturff@g.harvard.edu.ORCID 0000-0002-3356-4692
Florent-Valéry CoenLaboratory for Soft Bioelectronic Interfaces, Institute of Microengineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne (EPFL), 1202, Geneva, Switzerland.
Ariel E HightEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.
Osama TarabichiEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.
Vivek V KanumuriEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.
Nicolas VachicourasLaboratory for Soft Bioelectronic Interfaces, Institute of Microengineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne (EPFL), 1202, Geneva, Switzerland.
Stéphanie P LacourLaboratory for Soft Bioelectronic Interfaces, Institute of Microengineering, Institute of Bioengineering, Centre for Neuroprosthetics, École Polytechnique Fédérale de Lausanne (EPFL), 1202, Geneva, Switzerland.
Daniel J LeeEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.
M Christian BrownEaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.

Funding

DESCENDING SYSTEMS TO THE COCHLEA AND COCHLEAR NUCLEUSR01DC001089 · NIDCD · MASSACHUSETTS EYE AND EAR INFIRMARY · PI BROWN, M. CHRISTIAN · 1991 to 2019
$5.9M
NIDCD NIH HHS 01089NIDCD NIH HHS L30 DC006405Sinergia Grant from the Swiss National Science Foundation 530733
6 · The paper itself

Abstract

The auditory brainstem implant (ABI) is an auditory neuroprosthesis that provides hearing to deaf patients by electrically stimulating the cochlear nucleus (CN) of the brainstem. Whether such stimulation activates one or the other of the CN's two major subdivisions is not known. Here, we demonstrate clear response differences from the stimulation of the dorsal (D) vs. ventral (V) subdivisions of the CN in a mouse model of the ABI with a surface-stimulating electrode array. For the DCN, low levels of stimulation evoked multiunit responses in the inferior colliculus (IC) that were unimodally distributed with early latencies (avg. peak latency of 3.3 ms). However, high levels of stimulation evoked a bimodal distribution with the addition of a late latency response peak (avg. peak latency of 7.1 ms). For the VCN, in contrast, electrical stimulation elicited multiunit responses that were usually unimodal and had a latency similar to the DCN's late response. Local field potentials (LFP) from the IC showed components that correlated with early and late multiunit responses. Surgical cuts to sever the output of the DCN, the dorsal acoustic stria (DAS), gave insight into the origin of these early and late responses. Cuts eliminated early responses but had little-to-no effect on late responses. The early responses thus originate from cells that project through the DAS, such as DCN's pyramidal and giant cells. Late responses likely arise from the spread of stimulation from a DCN-placed electrode array to the VCN and could originate in bushy and/or stellate cells. In human ABI users, the spread of stimulation in the CN may result in abnormal response patterns that could hinder performance.

Indexed as

Auditory Brain Stem ImplantsCochlear NucleusInferior ColliculiAnimalsDecorinElectric StimulationEvoked Potentials, Auditory, Brain StemHearingHumansMiceDCN protein, humanDecorinCochlear nucleusDeafnessInferior colliculusLocal field potentialMultiunit activityNeuroprosthesis

Identifiers

PMID35381872
PMCPMC9085982

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.