Evidence map›Paper›PMID 35381114›Full record

ArticleMagnetic resonance in medicine2022

Ultrafast B1 mapping with RF-prepared 3D FLASH acquisition: Correcting the bias due to T

Dan Zhu, Michael Schär, Qin Qin

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Rapid 3D whole-brain high-resolution TMagnetic resonance in medicine · 2026
    Article
  2. Article
  3. Accelerated 3D multi-channelMagnetic resonance in medicine · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Rapid 3D absolute BMagnetic resonance in medicine · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Dan ZhuF.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.ORCID 0000-0002-0940-1519
Michael SchärThe Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA.ORCID 0000-0002-7044-9941
Qin QinF.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.ORCID 0000-0002-6432-2944

Funding

Sleep and Circadian Dysfunction, Brain and Neurobehavioral Development in AutismP50HD103538 · NICHD · HUGO W. MOSER RES INST KENNEDY KRIEGER · PI S. Ali Fatemi, Bradley L Schlaggar · 2020 to 2026
$9.9M
TRD 4: Platforms for multi-modal and multi-scale imaging dataP41EB031771 · NIBIB · HUGO W. MOSER RES INST KENNEDY KRIEGER · PI Hanzhang Lu, Peter CM Van Zijl · 2021 to 2026
$9.9M
Non-Contrast-Enhanced Velocity-Selective MR Angiography at 3T for Cerebrovascular DiseasesR01HL138182 · NHLBI · HUGO W. MOSER RES INST KENNEDY KRIEGER · PI QIN, QIN · 2018 to 2022
$2.0M
Velocity-Selective Arterial Spin Labeling based Perfusion Mapping for Cerebrovascular DiseasesR01HL144751 · NHLBI · HUGO W. MOSER RES INST KENNEDY KRIEGER · PI QIN, QIN · 2019 to 2022
$1.7M
NON-CONTRAST-ENHANCED PERIPHERAL MR ANGIOGRAPHYR01HL135500 · NHLBI · UNIVERSITY OF MARYLAND BALTIMORE · PI RAJAGOPALAN, SANJAY, WILSON, DAVID LYNN · 2017 to 2020
$1.5M
NHLBI NIH HHS R01 HL135500NHLBI NIH HHS R01 HL138182NHLBI NIH HHS R01 HL144751NIBIB NIH HHS P41 EB031771NICHD NIH HHS P50 HD103538NIH HHS R01 HL135500NIH HHS R01 HL138182NIH HHS R01 HL144751
6 · The paper itself

Abstract

purposeThe traditional radiofrequency (RF)-prepared B THEORY: The point spread function analysis of FLASH shows that the prepared longitudinal magnetization before the FLASH acquisition and the image signal obeys a linear (not proportional) relationship. The intercept of the linear function causes the quantification bias and can be captured by a third saturated scan.

methodsUsing the 2D double-angle method (DAM) as the reference, a 3D RF-prepared three-parameter protocol with 9 s duration was compared with the two-parameter method, as well as the saturated DAM (SDAM) method, the dual refocusing echo acquisition mode (DREAM) method, and the actual flip-angle imaging (AFI) method, for B

resultsThe 3D RF-prepared three-parameter method with complex-subtraction delivered consistently lower RMS error, error mean, error standard deviation, and higher concordance correlation coefficients values than the two-parameter method, the three-parameter method with magnitude-subtraction, the multi-slice DREAM and the 3D AFI, and were close to the results of 2D or multi-slice SDAM.

conclusionThe proposed ultrafast 3D RF-prepared three-parameter method with complex-subtraction was demonstrated with high accuracy for B

Indexed as

AlgorithmsMagnetic Resonance ImagingBrainPhantoms, ImagingRadio WavesReproducibility of Results3D FLASHB1 mappingcomplex-subtractionk-space filtering effectpoint spread functionRF-prepared B1 mapping

Identifiers

PMID35381114
PMCPMC9232926

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.