Evidence map›Paper›PMID 35373827›Full record

ArticleJournal of radiation research2022

Quantifying the dosimetric effects of neck contour changes and setup errors on the spinal cord in patients with nasopharyngeal carcinoma: establishing a rapid estimation method.

Yinghui Li, Zhanfu Wei, Zhibin Liu, Jianjian Teng, Yuanzhi Chang, Qiuying Xie, Liwen Zhang, Jinping Shi, Lixin Chen

Open access · goldAbstract read
In one paragraph

Article in Journal of radiation research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Yinghui LiState Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Sun Yat-Sen University of Medical Sciences, Guangzhou, 510060, Guangdong, China.
Zhanfu WeiRadiotherapy Center of the Oncology Medical Center, The First People's Hospital of ZhaoQing, Zhaoqing, 526000, Guangdong, China.
Zhibin LiuPhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Jianjian TengPhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Yuanzhi ChangPhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Qiuying XiePhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Liwen ZhangPhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Jinping ShiPhysics Department of the Radiotherapy Department, The First People's Hospital of FoShan (Affiliated FoShan Hospital of Sun Yat-sen University), Foshan, 528000, Guangdong, China.
Lixin ChenState Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Sun Yat-Sen University of Medical Sciences, Guangzhou, 510060, Guangdong, China.
First People's Hospital of Foshan · CNSun Yat-sen University · CNSun Yat-sen University Cancer Center · CNThe First People's Hospital of Zhaoqing · CN

Funding

Medical Science and Technology Foundation of Guangdong Province A2021186Spacial fund of Foshan Summit plan 2019D009
6 · The paper itself

Abstract

The purpose of this study was to quantify the effect of neck contour changes and setup errors on spinal cord (SC) doses during the treatment of nasopharyngeal carcinoma (NPC) and to establish a rapid dose estimation method. The setup errors and contour changes in 60 cone-beam computed tomography (CBCT) images of 10 NPC patients were analysed in different regions of the neck (C1-C3, C4-C5 and C6-C7). The actual delivered dose to the SC was calculated using the CBCT images, and univariate simulations were performed using the planning CT to evaluate the dose effects of each factor, and an index ${\mathrm{Dmax}}_{\mathrm{displaced}}$ was introduced to estimate the SC dose. Compared with the planned dose, the mean (maximum) Dmax increases in the C1-C3, C4-C5 and C6-C7 regions of the SC were 2.1% (12.3%), 1.8% (8.2%) and 2.5% (9.2%), respectively. The simulation results showed that the effects of setup error in the C1-C3, C4-C5 and C6-C7 regions were 1.5% (9.7%), 0.9% (8.2%) and 1.3% (6.3%), respectively, and the effects of contour change were 0.4% (1.7%), 0.7% (2.5%) and 1.5% (4.9%), respectively. The linear regression model can be used to estimate the dose effect of contour changes (R2 > 0.975) and setup errors (R2 = 0.989). Setup errors may lead to a significant increase in the SC dose in some patients. This study established a rapid dose estimation method, which is of great significance for the daily dose evaluation and the adaptive re-planning trigger of the SC.

Indexed as

Nasopharyngeal NeoplasmsRadiotherapy, Intensity-ModulatedCone-Beam Computed TomographyHumansNasopharyngeal CarcinomaRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedSpinal Cordcontour changedosimetric effectsnasopharyngeal carcinoma (NPC)setup errorspinal cord (SC)

Identifiers

PMID35373827
PMCPMC9124625
OpenAlexW4214828549

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.